background image

www.fmiproducts.com

124379-01A

8

Figure 9 - Lineal Gain

LINEAL GAIN

PART NO.

DESCRIPTION

GAIN

Georgian

Fireplace

66 

1

/

2

"

12-12DM

12-12HT

Pipe Section

10 

5

/

8

"

18-12DM

18-12HT

Pipe Section

16 

5

/

8

"

24-12DM

24-12HT

Pipe Section

23 

5

/

8

"

36-12DM

36-12HT

Pipe Section

34 

5

/

8

"

48-12DM

48-12HT

Pipe Section

46 

5

/

8

"

RLT-12D

RLT-12HT Round Termination

3

/

4

"

*

STL-12D Square Chase-Top 

with Slip Section

7"

 to 15

"

*

* The lineal gain for the terminations is mea

-

sured to the flue gas outlet height.

Hemmed 

End

12 

3

/

8

Stainless 

Inner Pipe

15" Galvanized 

Outer Pipe

ASSEMBLY AND INSTALLATION OF 

DOUBLE WALL CHIMNEY SYSTEM

Each double wall chimney section consists of a 

galvanized outer pipe, a stainless steel inner flue 

pipe and a wire spacer. The pipe sections must 

be assembled independently as the chimney is 

installed. When connecting chimney directly to 

the fireplace, the inner flue pipe section must 

be installed first with the lanced side up. The 

outer pipe section can then be installed over 

5 the flue pipe section with the hemmed end 

up. Press down on each pipe section until the 

lances securely engage the hem on the fireplace 

starter. The wire will assure the proper spacing 

between the inner and outer pipe sections.

Figure 8 - Outside Air Kit

Secure to Collars with Metal Tape, 

Screws or Straps (Min. of 1/4" x 20" 

in size)

Air Inlet 

Location 

Must Allow 

For Bushes 

or Snow

Vent Hood 

Required for 

Wall Installation

Air Inlet 

Eyebrow

Vented Crawl Space

(Check Local Codes 

Before Installing in a 

Vented Crawl Space)

CHIMNEY PIPE

The FMI PRODUCTS, LLC chimney system 

consists of 12", 18", 24", 36" and 48" snap-

lock,  double-wall  pipe  segments,  planned 

for  maximum  adaptability  to  individual  site 

requirements. Actual  lengths  gained  after 

fitting overlaps must be taken into consider

-

ation (lineal gain) and are given in the lineal 

gain chart (see Figure 9). Lineal Gain is the 

actual measurable length of a part after two or 

more parts are connected. For Canada, use 

chimney parts designated "HT".

VENTING INSTALLATION

OPTIONAL OUTSIDE AIR KIT 

(MODEL AK4/AK4F)

The  installation  of  an  outside  air  kit  should 

be  performed  during  the  rough  framing  of 

the fireplace due to the nature of it's location. 

Outside combustion air is accessed through 

a  vented  crawl  space  (AK4F)  or  through  a 

sidewall (AK4).

  CAUTION:  Combustion  air 

inlet ducts shall not terminate 

in attic space.

The  maximum  height  for  the 

air vent can not exceed 3 feet 

below the flue gas outlet of the 

termination.

 WARNING: The opening in 

the collar around the chimney at 

the top of the fireplace must not 

be obstructed. Never use blown 

insulation  to  fill  the  chimney 

enclosure.

Содержание G36A Series

Страница 1: ...with a vent free gas log heater approved to ANS Z21 11 2 standard This wood burning fireplace complies with UL127 CAN ULC S610 M87 standard as a FACTORY BUILT FIREPLACES FOR CANADA The authority havi...

Страница 2: ...cation in fireplace and refer to fire log warnings and caution markings on packaging prior to use Thisfireplaceisnotintendedtobe used as a substitute for a furnace to heat an entire home Use for suppl...

Страница 3: ...S 12 EACH SIDE COMBUSTIBLE WALL BOARD NO COMBUSTIBLE MATERIAL ON FACE MINIMUM 12 TO PERPENDICULAR SIDEWALL HEARTH EXTENSION 74 X 20 1 CHIMNEY AIRSPACE CLEARANCE TO COMBUSTIBLE MATERIAL OUTSIDE AIR 36...

Страница 4: ...GAS LINE KNOCKOUTS 12 EACH SIDE COMBUSTIBLE WALL BOARD NO COMBUSTIBLE MATERIAL ON FACE MINIMUM 18 TO PERPENDICULAR SIDEWALL HEARTH EXTENSION 66 X 20 2 CHIMNEY AIRSPACE CLEARANCE TO COMBUSTIBLE MATERIA...

Страница 5: ...OMBUSTIBLE MATERIAL COMBUSTIBLE WALL BOARD NO COMBUSTIBLE MATERIAL ON FACE 0 TO BOTTOM OUTSIDE AIR 11 2 AIR SPACE BACK AND SIDES GAS LINE KNOCKOUTS 12 EACH SIDE MINIMUM 18 TO PERPENDICULAR SIDEWALL HE...

Страница 6: ...nges Figure 5 Corner Installation SELECTING LOCATION To determine the safest and most efficient location for the fireplace you must take into consideration the following guidelines 1 The location must...

Страница 7: ...bustible material see Figure 6 WARNING Hearthextension is to be installed only as shown in Figure 6 FIREPLACE INSTALLATION Continued Figure 6 Hearth Extension Seal Gap Fireplace Front Ember Protector...

Страница 8: ...ns Figure 8 Outside Air Kit Secure to Collars with Metal Tape Screws or Straps Min of 1 4 x 20 in size Air Inlet Location Must Allow For Bushes or Snow Vent Hood Required for Wall Installation Air Inl...

Страница 9: ...ipe sections are locked to gether When installing double wall snap lock chimney together it is important to assure the joint between the chimney sections is locked Check by pulling chimney upward afte...

Страница 10: ...igure 14 Firestop Spacer with Attic Space Above Ceiling Existing Ceiling Frame Firestop Spacer Screws or Staples Min of 8 Firestop Spacer Screws or Staples Min of 8 PENETRATING ROOF To maintain a 1 36...

Страница 11: ...tom Overlap Shingles Top and Sides Only Figure 16 Flashing Installation FLASHING INSTALLATION V6F 10DM OR V12F 10DM Determine the flashing to be used with the roof opening chart Slide flashing over pi...

Страница 12: ...2 Min 10 3 Min 2 Min 3 Min Level of Flue Gas Outlet Figure 20 10 Foot Rule Terminations Spark Arrestor The fireplace system must be terminated with the listed round top or chase terminations In any c...

Страница 13: ...y should be postioned a distance apart as shown in Figure 21 4 Install rear refractory panel This panel has a top and bottom To determine which is which match up the pattern on the rear panel with the...

Страница 14: ...la tion from gas line conduit sleeve Save insulation for reuse Replace screws 3 Run a 1 2 black iron gas line into fireplace through the rear at gas line conduit sleeve if usingaraisedplatform addheig...

Страница 15: ...ce must comply with the Standard for Decorative Gas Appliance for Installation in Solid Fuel Burning Fireplaces ANS Z21 60 or Z21 84 and shall also be installed in accordance with the National Fuel Ga...

Страница 16: ...Installing Bi Fold Doors Spring Clip Insert Pin into Spring Clip Pivot Hole Insert Bottom Pivot Pin into Hole Fold Door and Slide Top Pins Into Track Figure 29 Adjusting Bi Fold Doors INSTALLING GLAS...

Страница 17: ...and a gradual temperature rise to 550 F which is more than a normal fire will generate Such materials as pitch wax laden logs very dry mill end lumber and large amounts of paper or cardboard boxes can...

Страница 18: ...www fmiproducts com 124379 01A 18 PARTS MODELS V G36 42 50 SERIES AND V J36 42 50 SERIES 1 21 20 5 6 7 10 9 11 12 13 16 17 15 14 8 24 23 3 25 18 2 22 19 4...

Страница 19: ...e 2 15 21171 Gas Conduit Cover 4 16 109752 01 Conduit One 2 17 109752 02 Conduit Two 2 18 Heat Shield Support 1 19 123298 02 Ash Box Assembly 1 20 Inner Dome Assembly 1 21 Smoke Shield 1 22 Damper Con...

Страница 20: ...www fmiproducts com 124379 01A 20 PARTS MODELS MODELS V G36 42 50 SERIES AND V J36 42 50 SERIES Picture may vary from actual 1 2 5 3 4 6 6...

Страница 21: ...1 125841 02 Right Herringbone 50 Red 1 3 116081 02 Left Stacked 36 Red 1 116086 02 Left Herringbone 36 Red 1 125833 02 Left Stacked 42 Red 1 125836 02 Left Herringbone 42 Red 1 125839 02 Left Stacked...

Страница 22: ...116081 01 Left Stacked 36 Natural White 1 116086 01 Left Herringbone 36 Natural White 1 125833 01 Left Stacked 42 Natural White 1 125836 01 Left Herringbone 42 Natural White 1 125839 01 Left Stacked 5...

Страница 23: ...tion or troubleshooting If so contact FMI PRODUCTS LLC at 1 866 328 4537 When calling please have your model and se rial numbers of your fireplace ready You can also visit our web site at www fmiprodu...

Страница 24: ...FLASHING V6F 10DM 0 to 6 12 Pitch V12F 10DM 6 12 to 12 12 Pitch ACCESSORIES Continued SQUARE CHASE TOP TERMINATION STL 12D AND STL 12DMP BLACK ROUND TOP TERMINATIONS RLT 12D AND RLT 12HT STORM COLLAR...

Отзывы: