background image

9

107600

OWNER’S MANUAL

For more information, visit www.desatech.com

INSTALLING REAR COVER

1.

Place rear cover behind stove body.
Rear cover will rest on the bottom ledge
of the stove body.

2.

Place wire harness from ON/OFF
switch under the cast of stove body.

3.

Using bolts provided, attach rear cover
to back of stove body. See Figure 21.

IMPORTANT:

 This rear cover must be

securely in place before venting pipes
are installed.

4.

Open lower door panel. The valve is
attached to the underside of the burner
system assembly.

5.

Connect one terminal of the wire from
ON/OFF switch to the THTP terminal
on the valve. Connect remaining wire
terminal to the TH terminal on the
valve. Make sure that the wire termi-
nals are in the positions on the unit as
pictured in Figure 22. If wires are not
connected as shown, the ON/OFF
switch will not work.

CAST IRON STOVE
AND B-VENT
BURNER SYSTEM
ASSEMBLY

Continued

 WARNING: Failure to position

the parts in accordance with sup-
plied diagrams or failure to use
only parts specifically approved
with this heater may result in dam-
age or personal injury.

 WARNING: A qualified in-

staller or service person must
connect burner system to gas
supply. Follow all local codes.

Figure 20 - Blower Wiring Layout

Green Ground Wire

Wiring Diagram Decal

Speed
Control
Box

Black
Wire

White
Wire

Blue Wire

Power Cord
(Route Through
Plastic Bushing in
Bottom Cover When
Assembled)

Screw

Figure 21 - Installing Rear Cover (Shown
with Optional Blower Accessory)

Rear Cover (Shown
with Optional Blower)

Hex
Bolts

15. Reattach bottom cover to rear cover

with 8 screws removed in step 2 on
page 8 (see Figure 18, page 8). Make
sure that you don’t pinch any wires
during reassembly.

Blower
Power
Cord

ON/OFF
Switch
Wire
Harness

ON/OFF
Switch

Figure 22 - Control Valve Terminals

To Control
Switch

INSTALLATION PRECAUTIONS

Consult local building codes before begin-
ning the installation. Only a qualified ser-
vice person should install venting system.
The installer must follow these safety rules:

• Wear gloves and safety glasses for

protection

• Use extreme caution when using ladders

or when on roof tops

• Be aware of electrical wiring locations

in walls and ceilings

The following actions will void the war-
ranty on your venting system:

• Installation of any damaged venting

component

• Unauthorized modification of the vent-

ing system

• Installation of any component part not

manufactured or approved by DESA
International

• Installation other than as instructed by

these instructions

Your burner system is approved for use with
any listed gas vent. A listed gas vent is a factory
made and listed system designed, and installed
exclusively for removing products of combus-
tion, excess air, and dilution air resulting from
burning fuel gas. Metal vents, the most com-
mon type of vent, employ double wall con-
struction enclosing an insulating air space.
This air space both helps keep flue gases warm
and reduce heat transferred to nearby combus-
tibles. This appliance is equipped with a safety
control system designed to protect against
improper venting of combustion products.

VENTING
INSTALLATION

 WARNING: Read all instruc-

tions completely and thoroughly
before attempting installation. Fail-
ure to do so could result in serious
injury, property damage, or loss of
life. Operation of improperly in-
stalled and maintained venting sys-
tem could result in serious injury,
property damage, or loss of life.

NOTICE: Failure to follow these
instructions will void the warranty.

Continued

Thermal
Switch

Содержание FSBVBNC

Страница 1: ...rational procedures For as sistance or additional information consult a qualified installer ser vice agency or the gas supplier WARNING If the information in this manual is not followed exactly a fire...

Страница 2: ...ndsealed If this unit is not properly installed by a quali fied service person with glass door properly seated and sealed gas leakage can occur Carbon Monoxide Poisoning Early signs of carbon monoxide...

Страница 3: ...gandventsvertically Heat is generated by both realistic flames and glowing embers When used without the blower accessory the stove with burner system requires no electricity making it ideal for emerge...

Страница 4: ...Figures 3 and 4 4 This stove is a freestanding unit de signed to set directly on the floor If your stove is to be installed directly on carpeting vinyl tile or any combustible material other than woo...

Страница 5: ...e Figure 7 Rest stove on drop cloth orblankettoavoidscratchingstoveedges 7 Remove remaining pallet wood at tached to bottom of stove body see Figure 8 Use an adjustable wrench to remove bolts 8 Fasten...

Страница 6: ...ed surface Remove the two screws that hold the front plate onto the front surround plate see Figure 14 Save these screws 15 Remove the seven screws and washers that hold the screen onto the front sur...

Страница 7: ...nector plate over gasket and align holes Secure with hex screws provided see Figure 17 IMPORTANT Gasketandconnectingplate must not be installed until after burner sys tem has been inserted into stove...

Страница 8: ...bypushingand turning lock nut with pliers clockwise until tight against the side of rear cover Place control knob provided onto shaft 7 Placethegreen ground wirebetweenthe bottom hole on the blower as...

Страница 9: ...ge 8 Make sure that you don t pinch any wires during reassembly Blower Power Cord ON OFF Switch Wire Harness ON OFF Switch Figure 22 Control Valve Terminals To Control Switch INSTALLATION PRECAUTIONS...

Страница 10: ...elect the correct gas vent di ameter Avoid using a larger than nec essary diameter It is very important that the venting system maintain its balance between the combus tion air intake and the flue gas...

Страница 11: ...nt ing applications NOTICE A complete chimney inspection by a qualified person should be performed Appliances using B vent connectors to vent into a masonry or factory built chimney should not exceed...

Страница 12: ...s and or noticeable odors Spillage may also result in the release of carbonmonoxide acolorless odorless highly toxic gas A simple spillage test can be con ducted if spillage is suspected See Checking...

Страница 13: ...exposed to extremely cold tem peraturesorventingofsinglewallconstruc tion loses heat needed to maintain draft massive masonry chimneys absorb needed heat Ifthefluegasescoolexcessively draft is reduced...

Страница 14: ...ded by Installer Equipment Shutoff Valve To Gas Supply Natural Figure 32 Attaching Flexible Gas Lines Together Figure 31 Gas Connection The CSA AGA design certified equipment shutoff valve may be supp...

Страница 15: ...all gas joints Bubbles forming show a leak Correct all leaks at once Pressure Testing Burner System Gas Connections 1 Open equipment shutoff valve see Fig ure 33 2 Open propane LP supply tank valve f...

Страница 16: ...the base see Figure 37 WARNING Do not connect this thermostat to a power source Electrical shock and or fire hazard will occur Figure37 BackViewofThermostatBase Feed wires through rectangular slots F...

Страница 17: ...g Receiver Battery Clip Terminal Wires LO H I P I L O T OFF ON Figure 40 Installing Remote Receiver 2 Remove the screws from the 2 tabs at the top of the glass door while holding door securely keeping...

Страница 18: ...OGS LAVA ROCK AND GLOWING EMBERS STOVE AND B VENT BURNER SYSTEM INSTALLATION Continued 1 2 3 4 Figure 45 Installing Log No 1 Figure 46 Installing Log No 2 Figure 47 Installing Log No 3 Figure 48 Insta...

Страница 19: ...push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a f...

Страница 20: ...ll remain lit GHRCTA Series Operation 2b Press the AUTO ON OFF button on the hand held remote control see Figure 52 The lights to the left of the button will show AUTO ON or OFF In the ON mode the bur...

Страница 21: ...AL BLOWER ACCESSORY Blower controls are located on the left side of the rear cover of stove from front of stove The DA3610TA thermostatically con trolled blower has an ON setting and an OFF setting Th...

Страница 22: ...parts sup pliedbythemanufacturershould be used when replacing broken ordamagedglassdoorpanel see ReplacementParts page26 This glass door panel is a complete unit No substitute materials may be used If...

Страница 23: ...ot fully open 4 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor Nut is located...

Страница 24: ...e 2 Operate burner until air is removed from line Have gas line checked by local pro pane LP or natural gas company 3 Clean burner see Cleaning and Maintenance page 22 or replace burner orifice 1 Adju...

Страница 25: ...valve defective 1 Gas leak See Warning statement above 1 Improper log placement 2 Air holes at burner inlet blocked 3 Burner flame holes blocked OBSERVED PROBLEM Burner system produces unwanted odors...

Страница 26: ...disconnection when servicing controls Wiringerrorscancause improper and dangerous opera tion Verify proper operation af ter servicing Note Use only original replacement parts Thiswillprotectyourwarran...

Страница 27: ...t at 1 800 432 2382 for information You can also write to the address listed on the back page of this manual WALL MOUNTED THERMOSTAT CONTROL KIT GWMT1 Not Shown Allows easy wall access to the operatio...

Страница 28: ...TEM 107600 For more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN FSBVBNC FSBVBPC LO H I P I L O T OFF ON 4 4 17 18 19 21 23 1 23 4 23 2 23 3 27 4 22 10 5 11 8 1 9 25 4 13 14 15 20 20...

Страница 29: ...t 1 13 105489 01 Valve Natural 1 105489 02 Valve Propane LP 1 14 105488 01 Pilot Assembly Natural 1 105488 02 Pilot Assembly Propane LP 1 15 102445 01 Ignitor Piezo 1 16 106854 01 4 Connector Gasket 1...

Страница 30: ...AST IRON STOVE AND BURNER SYSTEM 107600 For more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN FMI STOVE P FC SERIES 1R 1C 1L 5 8 8 7 4 6 5 5 7 1 7 2 5 4 7 3 2 3 Discarded During Asse...

Страница 31: ...celain Enamel Green 4 Total Per Stove 1 104175 15 One Leg Porcelain Enamel Red 4 Total Per Stove 1 6 104176 01 Leg Leveler bolt M8 x 1 25 55mm Long 4 Total Per Stove 1 7 104177 02 Hardware Kit 1 7 1 D...

Страница 32: ...ted to repairing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTH...

Отзывы: