TROUbLEShOOTING

Continued 

 WARNING: If you smell gas

•  Shut off gas supply.

•  Do not try to light any appliance.

•  Do not touch any electrical switch; do not use any phone in your 

building.

•  Immediately call your gas supplier from a neighbor’s phone. Fol

-

low the gas supplier’s instructions.

•  If you cannot reach your gas supplier, call the fire department.

IMPORTANT:

 Operating log set where impurities in air exist may create odors. Cleaning sup

-

plies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., 
create fumes. These fumes may mix with combustion air and create odors. These odors will 

disappear.over.time..

POSSIBLE CAUSE

1. Metal  expanding  while 

heating. or. contracting.

while cooling

1..Log. set. burning. vapors.

from  paint,  hair  spray, 
glues,  cleaners,  chemi

-

cals, new carpet, etc. (See 

IMPORTANT

. statement.

above)

2. Gas  leak. 

See  Warn-

ing  statement  at  top  of 
page

1. Gas  leak. 

See  Warn-

ing  statement  at  top  of 
page

2..Control.valve.defective

1. Gas  leak. 

See  Warn-

ing  statement  at  top  of 
page

OBSERVED PROBLEM

Log  set  produces  a  clicking/
ticking noise just after burner 

is.lit.or.shut.off

Log  set  produces  unwanted 

odors

Gas odor even when control 

knob.is.in.OFF.position

Gas odor during combustion

REMEDY

1. This is normal with most log 

sets. If noise is excessive, 

contact. qualified. service.
person

1..Open. flue. to. maximum..

Stop. using. odor. causing.

products  while  log  set  is 

running

2..Locate.and.correct.all.leaks.

(see.

Checking  Gas  Con

-

nections

, page 7)

1..Locate.and.correct.all.leaks.

(see.

Checking  Gas  Con

-

nections

, page 7)

2..Replace.control.valve

1..Locate.and.correct.all.leaks.

(see.

Checking  Gas  Con

-

nections

, page 7)

TEChNICAL SERVICE

You may have further questions about installa

-

tion, operation, or troubleshooting. If so, con

-

tact DESA Heating, LLC at 1-866-672-6040. 

When. calling. please. have. your. model. and.
serial.numbers.of.your.heater.ready.

You can also visit DESA Heating, LLC’s web 

site.at.

www.desatech.com

.

SERVICE hINTS

When Gas Pressure is Too Low

•  pilot will not stay lit
•  burners will have delayed ignition
•  heater will not produce specified heat
•  propane/LP gas supply may be low
You may feel your gas pressure is too low. If 
so, contact your local propane/LP or natural 

gas.supplier.

Содержание BCS18

Страница 1: ...gassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali fied installer service agency or the gas supplier INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference VENTED DECORATIVE NATURAL GAS LOG APPLIANCE OWNER S OPERATION AND...

Страница 2: ...led Provisionsforadequatecombus tion and ventilation air must be provided Refer to the National Fuel Gas Codes ANSI Z233 1 NFPA54 AirforCombustionand Ventilation This appliance may be installed in an aftermarket permanently located manufactured mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not con...

Страница 3: ...irectlyintothefireplace Ceiling fans can create drafts that alter burner flame patterns Avoidanydraftsthatalterburner flame patterns SAFETY Continued Due to high temperatures the appliance should be located out oftrafficandawayfromfurniture and draperies Do not place clothing or other flammable material on or near the appliance Never place any objects on the appliance Log set becomes very hot when...

Страница 4: ...for combus tion and ventilation air must conform with the National Fuel Gas Code ANSI Z233 1 NFPA 54 Air for Combustion and Ventilation SAFETY Continued Product Identification Figure 1 Product Identification Ramp Pan Burner Grate Burner Pan Burner Inlet Under Pan 7 Do not run log set where flammable liquids or vapors are used or stored under dusty conditions 8 Do not burn solid fuel in fireplace a...

Страница 5: ... sote will ignite if highly heated A dirty chimney flue may create and distribute soot within the house Inspect chimney flue for damage If damaged repair flue before operating heater NOTICE Installation service andrepairofthisappliancemust be performed by a qualified in staller serviceagency company orgassupplierexperiencedwith this type of gas appliance Only factory authorized components listed i...

Страница 6: ... resistant to Propane LP gas equipment shutoff valve test gauge connection adjustable crescent wrench or pliers sediment trap tee joint pipe wrench CHECK GAS TYPE Use only natural gas If your gas supply is not natural gas you MUST NOT install this gas log set WARNING This appliance is equipped for natural gas Field conversion is not permitted If fireplace does not have a gas supply shutoff valve o...

Страница 7: ...LLATION Continued We recommend that you install a sediment trap in supply line as shown in Figure 4 Locate sediment trap where it is within reach for cleaning Install in piping system between fuel supply and heater Locate sediment trap where trapped matter is not likely to freeze A sediment trap traps moisture and contami nants This keeps them from going into log set controls If sediment trap is n...

Страница 8: ...f gas connector tube to gas inlet fitting on end of venturi Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve see Fig ure 5 2 Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter 3 Check all joints from gas meter to equip ment shutoff valve see Figure 6 Apply noncorrosive leak detection fluid to ga...

Страница 9: ...here two outer horizontal supports on grate fit into two pan positioning tabs on outer edges of pan 2 Place large back log on grate at top tier rear of ramp see Figure 8 3 Figures 8 and 9 show a suggested log arrangement however you may arrange logs as you wish Leave as much open space between logs as possible to mini mize flame impingement and sooting Note Logs may chip if they are handled roughl...

Страница 10: ...hat is not cause for alarm However you may want to provide extra ventilation to the room during this time Cleaning and Maintenance FOR YOUR SAFETY READ BEFORE LIGHTING WARNING Keep flue open when operating unit WARNING If you do not fol low these instructions exactly a fire or explosion may result causing property damage per sonal injury or loss of life BEFORE LIGHTING smell all around the ap plia...

Страница 11: ...venting system not drafting properly 3 Excessive flame impinge ment or blockage 4 Improper fuel air mixture 5 Excessive gas supply pressure 1 Passage of air gas across irregular surfaces 1 Incorrect gas supply or pressure 2 Blocked burner orifice or burner manifold ports 3 Improper burner orifice size REMEDY 1 Contact local natural or propane LP gas company 2 Adjust damper wide open and or have fi...

Страница 12: ...ement at top of page OBSERVED PROBLEM Log set produces a clicking ticking noise just after burner is lit or shut off Log set produces unwanted odors Gas odor even when control knob is in OFF position Gas odor during combustion REMEDY 1 This is normal with most log sets If noise is excessive contact qualified service person 1 Open flue to maximum Stop using odor causing products while log set is ru...

Страница 13: ...essories call DESAHeating LLC at 1 866 672 6040 for information You can also write to the address listed on the back page of this manual Individual Round Log GA9450A For decorative purposes only Not to be used as additional logs on unit Individual Split Log GA9550A For decorative purposes only Not to be used as additional logs on unit Pine Cones GA9650A For all models Use for additional decoration...

Страница 14: ...www desatech com 115425 01E 14 Parts Models PHK18 PHK24 PHK30 BCS18 BCS24 and bcs30 Number and style of logs vary by model 1 8 23 17 10 18 11 13 24 9 3 2 4 5 6 7 22 15 16 20 12 21 19 14 ...

Страница 15: ...6 14527 Venturi Gasket 1 7 115482 01 Burner Pan 1 115482 02 Burner Pan 1 115482 03 Burner Pan 1 8 901242 01 Damper Clamp Assembly 1 9 11209 Nut 10 24 2 10 114986 01 Log Grate 1 114986 02 Log Grate 1 114986 03 Log Grate 1 11 901481 01 Bottom Log 1 109128 02 Bottom Log 1 109128 01 Bottom Log 1 12 111827 08 Small Log 1 13 112489 01 Small Log 1 14 109399 01 Small Log 1 15 115421 02 Small Log 1 16 1119...

Страница 16: ...ded by a DESA Heating LLC Authorized Service Center or a provider approved by DESA Heating LLC Warranty parts must be obtained through authorized dealers of this prod uct and or DESA Heating LLC who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic material labor and incidental costs assoc...

Отзывы: