MANTELS: 

A mantel may be installed if desired (see figure 24). 
Woodwork such as wood trims, mantels, or any other 
combustible material projecting from the front face must not 
be placed within 9 inches of the fireplace opening. 
Combustible materials above 9 inches and projecting more 
than 1 -1/2 inches from the fireplace face must not be placed 
less than 12 inches from the top of the opening of the fireplace 
(NFPA STD 211, Sec. 7-3.3.3). 
 
 

 

 

Mantels or any other combustible materials also may come up 
to the side periphery of the black metal face of the fireplace as 
long as the projection from the front face falls within the limits 
depicted in figure 25.  

 
 

 
 
 
 
 
 
 
 
 

WARNING:

  Risk of fire; Replace grate with FMI Model 

36E GR grate only. 

 
DAMPER OPERATION: 

The damper handle to open and close the damper blade is 
located inside the firebox at the center towards the back wall.  
Pushing the handle back in the keyway slot will free the 
damper blade to automatically open.  To close, reach in and 
push the handle back into the keyhole slot then pull down and 
forward to lock it in place (see figure 26). 
 

WARNING:

 Damper handle will remain hot even after there 

is no fire in the fireplace.  Make sure it cools down before 
touching the handle. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
FOR FURTHER OPERATING GUIDELINES, 
INSTRUCTIONS AND WARRANTY INFORMATION 
PLEASE REFER TO YOUR HOMEOWNERS GUIDE OR 
CONTACT YOUR AUTHORIZED DEALER. 
 

 
 
TECHNICAL SERVICE 

 
You may have further questions about installation, operations, 
or troubleshooting.  If so, contact FMI/DESA International’s 
Technical Service Department at 1-888-427-8322.  When 
calling FMI/DESA International, have the model number of 
your fireplace ready. 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Figure 24 

 
 
 
 
 
 
 
 
 

 
 

 
 
 
Figure 25

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 
Figure 26

 

Содержание 36ECD

Страница 1: ...ional accessory items when needed Keep it with your other important papers This Fireplace is approved for use as a Wood Burning Fireplace or for use with a vented gas log approved to ANS Z21 60 Z21 84 or RGA 2 72 Standards or for use with a vent free gas log heater approved to ANS Z21 11 2 standard WARNING ALWAYS LEAVE GLASS DOORS FULLY OPENED OR FULLY CLOSED WHEN OPERATING THIS FIREPLACE 36 Wood ...

Страница 2: ...chimney sections and the effective height of the termination assembly INSTALLING THE FIREPLACE STEP 1 Frame the opening for the fireplace using the dimensions shown in FIGURE 1 2 or 3 STEP 2 If the fireplace is to be installed directly on carpeting tile other than ceramic or any combustible material other than wood flooring the fireplace must be installed upon a metal or wood panel extending the f...

Страница 3: ...REPLACE MUST NOT BE OBSTRUCTED NEVER USE BLOWN INSULATION TO FILL THE CHIMNEY ENCLOSURE SEE FIG 5 Continue to assemble chimney sections as outlined above making sure that both the inner and outer pipe sections are locked together When installing double wall snap lock chimney together it is important to assure the joint between the chimney sections is locked Check by pulling chimney upward after lo...

Страница 4: ...r a given span usually 12 inches A 6 12 pitch means that the roof drops 6 inches for each 12 inches one measures horizontally down the roof STEP 3 Use the roof opening chart below to determine the correct opening length and flashing required see figure 8 STEP 4 Remove the shingles around the opening measured and cut out this section STEP 5 Add the next sections of the pipe until the end penetrates...

Страница 5: ...t smoke spillage from one termination to another We suggest that terminations be separated at least 30 inches center to center and stacked at vertical height difference of 18 inches see figure 12 10 FOOT RULE All chimney terminations must extend a minimum of 3 feet in height above the highest point where it passes through the roof and must be at least 2 feet above the peak of the roof if within a ...

Страница 6: ... per chimney system SEE FIGE 17 Figure 17 TYPICAL OFFSET INSTALLATION Figure 15 OFFSET RISE A B 48 36 24 18 12 4 3 8 16 3 8 9 3 4 25 1 2 1 12 3 4 30 3 4 1 15 34 3 4 1 18 40 1 1 21 1 4 46 1 4 1 23 3 4 49 1 4 1 1 27 3 4 56 3 4 1 30 60 3 4 1 1 33 66 1 1 36 71 1 1 38 1 4 75 2 41 1 4 80 1 4 1 1 1 45 86 3 4 2 46 3 4 89 1 2 1 1 1 51 97 1 1 53 1 4 101 2 1 56 1 4 106 1 4 2 59 1 4 111 1 2 1 1 1 61 3 4 115 1...

Страница 7: ...fractory knockout hole with refractory cement or commercial furnace cement Install the decorative gas appliance or cap off gas line if desired The gas pipe is intended for connection to a decorative gas appliance vented gas log If you wish to install an unvented gas log set ONLY UNVENTED GAS LOG SETS WHICH HAVE BEEN FOUND TO COMPLY WITH THE STANDARD FOR UNVENTED ROOM HEATERS ANS Z21 11 2 ARE TO BE...

Страница 8: ...facturer or supplier of the non combustible material If the hearth extension is to be covered use non combustible material such as tile slate brick concrete metal glass marble stone etc Fasten the hearth extension to the floor to prevent shifting and seal the gap between the fireplace frame and hearth extension with a non combustible material see figure 22 WARNING HEARTH EXTENSION IS TO BE INSTALL...

Страница 9: ... OPERATION The damper handle to open and close the damper blade is located inside the firebox at the center towards the back wall Pushing the handle back in the keyway slot will free the damper blade to automatically open To close reach in and push the handle back into the keyhole slot then pull down and forward to lock it in place see figure 26 WARNING Damper handle will remain hot even after the...

Страница 10: ...9 REPLACEMENT PARTS ACCESSORY PARTS ...

Отзывы: