To access the dynamic displays for the recipes the
operator must enter a five digit number (i.e., 50100).
The first digit represents the recipe dynamic dis-
plays. The second and third digits represent the
recipe (01 through 24) displays that are to be dis-
played. The fourth and fifth digits identify a specific
dynamic display.
EXAMPLE 50101
Where: 5 = Display Identifier
(Recipe)
01 = Recipe #
01 = Dynamic Display
The dynamic display from the recipe display that is
represented by 50101 is from recipe 01 and is:
Raw Total 000000311
1. To select a dynamic display from a recipe (i.e.,
50202), press “ENTER 5”. The display will read:
Recipe Dyn Display
2. “ENTER 02” for the recipe number. The display
will read:
Recipe 02 Dyn Display
3. “ENTER 02” for dynamic display 02, the display
will read:
Recipe 02 Dyn Display 02
then it will automatically switch to:
Grs Total 000000300
4. To step through the dynamic displays, press
“ENTER” and AccuLoad II will step through the
dynamic displays sequentially each time “EN-
TER” is pressed.
Gst Total 000000296
5. Press “ENTER”.
Net Total 000000000
6. To revert back to the preset display, press
“CLEAR”.
600 Gal P 1000 400
Note: All recipe dynamic displays can be viewed individually by
simply entering the five digit number indicating the recipe number
and dynamic display required (i.e., 52401).
To access the dynamic displays for batch the op-
erator must enter a four digit number (i.e., 6101).
The first digit represents the batch dynamic displays.
The second digit represents the batch (1 through 6)
displays that are to be displayed. The third and
fourth digits identify a specific dynamic display (See
Batch Display Reference).
EXAMPLE 6101
Where: 6 = Display Identifier
(Batch)
1 = Batch #
01 = Dynamic Display
The dynamic display from the batch display that is
represented by 6101 is from batch number 1 and is:
Raw Batch 1000.84
where Midgrade is the description programmed into
the recipe that was loaded in batch number 1.
1. To select a dynamic display from a batch (i.e.,
6202) press “ENTER 6”, the display will read:
Batch 2 Dyn Display
2. “ENTER 2” for the batch number, the display will
read: