32 (40)
EN
Troubleshooting
Fault
Possible cause
Action
Page
No water comes out when
the mixer is
turned on
Insufficient supply voltage
Replace the battery/Check the voltage
Blocked inlet filters
Clean the inlet filters
Blocked solenoid valve filter
Clean the solenoid valve.
Defective solenoid valve.
Replace the solenoid valve
Mixer does not turn off
Extended/sustained flushing
activated
Press a finger against the ring on the sensor
to turn the water off, or wait up to 60 seconds
for the water to stop running.
Hygiene flush in progress.
The yellow LED is flashing
Wait 3 to 30 minutes or briefly disconnect
the power supply. (Yellow LED flashes during
hygiene flushing)
Wrong solenoid valve
Replace the solenoid valve
Flush time set too high
Wait up to 30 seconds Reset the sensor.
The mixer starts running
without being turned on
The mixer is in hygiene flush mode.
The yellow LED is flashing.
Turn off the hygiene flush mode via WMS
Water is dripping from
mixer's spout/shower
Leaking solenoid valve
Replace the solenoid valve
Water residue in overhead shower
head
Adjust the overhead shower head to
horizontal position
The sensor flashes yellow
but still works
Low battery
Replace the battery
The sensor flashes red and
doesn't work
Flat battery
Replace the battery
The temperature is not
correct
Incorrect water pressure and
temperature
Set the temperature value to the coldest/
hottest setting and check that the water
pressure and temperature are high enough
The temperature limiter function is
set incorrectly
Set the temperature limiter to its hottest
setting and check the temperature. Adjust the
temperature limiter
The water pressure is too
low
Blocked aerator
Clean or replace the aerator
Blocked inlet filters
Clean or replace the inlet filters
Blocked solenoid valve filter
Clean or replace the solenoid valve
The mixer does not respond
when temperature is
adjusted
The mixer is incorrectly connected
or the hot water supply is
incorrectly installed
The hot water should be connected to the left
side of the mixer
The mixer is activated
by reflective clothing
Nothing is wrong. IR light is
strongly reflected by reflective
material, and this activates the
mixer
Models with an underlying spout are less
sensitive to reflex clothing
The shower duration varies
between 1 and 5 minutes
Nothing is wrong. The shower
may run up to 5 minutes if
the user is close to the mixer
Change the programme or settings via WMS 28, 27
Flushtime is too short or
too long.
Nothing is wrong. The flushtime is
adjustable
Change settings via WMS