CABLES
IMPORTANT

Use only 1.00mm

2

size cable up to 40 metres

length maximum.   

Maximum rating :

1.00mm

2

size cable, 10 amps 250 volts AC.

THE MICRO LITE IS SUPPLIED WITH CABLE
WIRED DIRECTLY INTO THE PRODUCT.

1.

Flymo Mains Cables and Extension Cables are
available from your local Approved Service
Centre.  

2.

Do not wire an extension cable directly to your
product yourself.  Please contact your local
Approved Service Centre for further information
on the connectors and kits available.  

3.

Only use extension cables specifically designed
for outdoor use.

CONNECTORS
IMPORTANT

Flymo connectors are suitable for use with 2
core cable only.  Under no circumstances should
these connectors be used for earthed products.

All Flymo connectors and cables are of splash-
proof construction.  They are not waterproof
and must not be left outside permanently nor
should they be submerged or immersed in
water.  Do not let cable lay or trail through pools
of water or splashed with water from hose
pipes.

MAINS PLUG REPLACEMENT
IMPORTANT

If the plug supplied is cut off it should be
d e s t royed. There is an electric shock hazard if

a cut off plug is inserted into a 13 amp socket.

1.

No earth required. 

Flymo products are double

insulated to EN60335  and under no circum-
stances should an earth be connected to any
part of the product.

2.

Ensure the mains voltage suits your product

3.

IMPORTANT!  

The wires in the mains lead are coloured in
accordance with the following code:
BLUE         -      NEUTRAL
BROWN     -      LIVE
The wire which is coloured BLUE must be con-
nected to the Terminal which is marked with the
letter 'N' or coloured BLACK.  
The wire which is coloured BROWN must be
connected to the Terminal which is marked with
the letter 'L' or coloured RED. 

4.

It is important that the outer sheath is clamped
correctly into the 3-pin plug. 

5 .

If in doubt consult your local Service Repairer or
qualified electrician before the machine is used.  

6.

A 13 Amp fuse must be fitted to the Mains
Plug.   

7.

The normal plug fuse and household fuse only
protect the electrical equipment and are not a
safeguard against electrocution.

A

Lower Handle to Hood Assembly (A)

Ensure the motor cover is fitted correctly,
as illustrated

Tilt motor cover into forward position
before assembly

1.

Insert lower handles through the 2 holes in the
motor cover and push down.

2.

Secure lower handles to hood by firmly push-
ing fixing pins through holes in motor cover,
handle and hood.

Fitting Upper Handles to Lower Handles (B)

1.

Ensure the upper handle is located correctly
with the lock-off button on the switchbox upper-
most

2.

Ensure the upper handle and the lower handle
are aligned correctly.

3.

Insert the nut into the handle knob 

(B1)

.

4.

Fit the bolts, washers and handle knobs 

(B2)

.

5.

Fit the cable to the handles with the clips provid-
ed 

(B3)

. Make sure the cable is not trapped

between the handles.

Assembly Instructions

If your product is hard wired i.e. non-detach-
able mains electric cable, a conversion kit and
extension cable is available from all Approved
Service Centres which can be found in your
local Yellow Pages.

B

lock-off

button

1

2

3

Содержание MLite 28

Страница 1: ...For all customer enquiries or for replacement parts contact 0870 609 1901 www flymo com customer services husqvarna co uk ...

Страница 2: ...d efficiency in using this product The operator is responsible for following the warning and safety instructions in this manual and on the product Explanation of Symbols on the Micro Lite Warning Read the user instructions carefully to make sure you understand all the con trols and what they do Switch off Remove plug from mains before adjusting cleaning or if cable is entangled or damaged Keep the...

Страница 3: ...ear substantial footwear and long trousers 2 Make sure the lawn is clear of sticks stones bones wire and debris they could be thrown by the plastic cutters 3 Before using the machine and after any impact check for signs of wear or damage and repair as necessary 4 Replace worn or damaged plastic cutters together with their fixings in sets to preserve balance Use 1 Use the product only in daylight o...

Страница 4: ...following code BLUE NEUTRAL BROWN LIVE The wire which is coloured BLUE must be con nected to the Terminal which is marked with the letter N or coloured BLACK The wire which is coloured BROWN must be connected to the Terminal which is marked with the letter L or coloured RED 4 It is important that the outer sheath is clamped correctly into the 3 pin plug 5 If in doubt consult your local Service Rep...

Страница 5: ...the lawn NOTE There are two start stop levers fitted Either one can be used for starting the product IMPORTANT Do not use the start stop levers intermittent ly To Stop your Product 1 To prevent a ring being cut in your lawn tilt your product slightly E 2 Release the pressure on the Start Stop lever Starting and Stopping C D E F G 1 How to Use 1 Start cutting the edge of the lawn nearest to the pow...

Страница 6: ... M The cutting system must be kept in good condi tion and inspected before and after use Disconnect from the mains electricity supply and wait until the cutting head has stopped rotating Turn your product upside down 1 Visually check cutting head for wear Replace if damaged 2 Visually check plastic cutters for wear and replace when necessary 3 Plastic cutters should be straight Replace if bent or ...

Страница 7: ... in a professional application 2 Always use genuine Flymo Spare Parts 3 Prepacked spares are available from most Husqvarna Outdoor Products stockists 4 Your product is uniquely identified by a silver and black product rating label 5 If you have a problem with your machine contact your local Approved Service Centre ensuring you have full details of your product as described on the product rating la...

Страница 8: ... Plastic Cutters Cutting Head Electric Mains cable Caution Husqvarna Outdoor Products does not accept liability under the warranty for defects caused in whole or part directly or indirectly by the fitting of replacement parts or additional parts that are not either manufactured or approved by Husqvarna Outdoor Products or by the machine having been modified in any way Guarantee Guarantee Policy I ...

Отзывы: