![FLYGT APP700 Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/flygt/app700/app700_installation-manual_2311479016.webp)
Terminal
Input signal no./Description
+33/–34
16
+35/–36
Internal 24V DC power supply to digital input signals.
Signal requirements
The signal requirements are:
• Logical 0 = –3 to +5V.
• Logical 1 = 11–30V, 6–30mA.
Connect Digital Outputs
WARNING:
Always take care when making connections and carrying out service work; these outputs
may be at high voltage.
General instruction
Connect the digital outputs according to the following instructions:
• Connection drawing, and
• Terminals.
Connection drawing
This is a connection drawing of the digital outputs.
Figure 10
Terminals
This table gives an overview of the terminals for digital outputs.
Table 8
Terminal
Output signal no.
Type/Rated for
53/54
1
Relay output
2A, 250V, AC/DC
55/56
2
57/58
3
59/60
4
61/62
5
63/64
6
65/66
7
Semiconductor output
100 mA, 250V AC/DC
67/68
8
Connect Inputs and Outputs