Instrument settings
Space unit:
set the unit of measure for the distance
between Kilometers (km) and Nautical Miles (NM).
Q.ty unit:
set the unit of measure for the fuel between
Liters (lt) and U.S. Gallons (gal).
Tank cap:
set the total capacity on-board as the sum of
all the usable fuel in all tanks. (range 0-500lt, 0-132 gal.)
K-factor:
the K-factor of a fuel flow transducer is the
number of electric pulses for 1 gallon of fuel flown (if you
have the K-factor in liters you must multiply this value by
3.78 before set k-factor parameter in the instrument).
If you are using the RED-CUBE FT-60 flow sensor Flybox
code 503030, make sure the K factor is 68000.
If you are using another kind of Fuel Flow sensor, make
sure about his compatibility of the electrical signals of
amplitude and frequency and follows the manufacturer
instructions to set the right K-factor in the “K-Factor”
parameter.
The K-factor can be manually modified or automatically
calculated with the “K-fact calib” function. It's
recommended also to execute the K-factor calibration as
soon as possible to have the maximum accuracy (refer to
chapter
4.5.1
“K-fact calib”).
To manually edit the K-factor select and click on the
K-Factor parameter. Rotate the knob to set the first 2 digit,
confirm them pushing the knob, modify the last 3 digit and
confirm them pushing the knob.