Omnia57
Fuel Comp
-
Installation and User Manual,
Safety Instructions and Warning Booklet
FLYBOX
Rev. 1.0
®
13
Electrical installation
PIN
I/O
Signal
1
I
+V Main supply, 10-30Vdc, with a proper
breaker
2
O
Vout for sensors, it delivers the same
voltage supplied on the Pin 1, short
circuit protected and limited to 500mA
3
O
5V out for sensor, short circuit protected
and limited to 350mA
7
I
Fuel Pressure input
8
I
Fuel Flow 1 Input
9
I
Fuel Flow 2 Input
11
I
COM 1 RX for GPS
12
I
GND main supply
13
O
Alarm Out, NPN 300 mA (not protected)
14
I
Ambient light sensor input
15
I
External switch
3.3 - (22 POLE) CONNECTOR TABLE
Molex P/N 43025-2200
(22 pole housing). View
from wire insertion side.
1
11
22
12
Содержание Omnia57 Series
Страница 4: ...Examples of different screens ...