Capacity Limit
The charging capacity is calculated as the charging current multiplied by time. If the charging
capacity exceeds the design capacity of the battery, it indicates a malfunction, therefore the
process will be terminated automatically.
Temperature Threshold
2
The internal resistance and the internal chemical reaction will cause the battery to heat up
during use. An excessive overheating however indicates a malfunction, therefore when the
threshold temperature is reached, the running program will be terminated automatically.
Time Limit
During normal operation, the programs will end after a predefined amount of time, exceeding
this time limit indicates a malfunction, the running program will be terminated automatically.
USB Power 5V/2.1A
Phone, tablets and other USB-
powered devices can be charger
using the built-in USB port.