14 / 28
Attachment Drum pumps FP 430 Ex S-41/38 FOOD and FP 427 S-43/38 FOOD
ENGLI
SH
3
Cleaning
3.1
FP 430 Ex S-41/38 FOOD
> Pull the mains plug and shut off the compressed air, respectively, and disconnect
the supply.
> Loosen the union nut (connection between motor and pump).
> Take the motor off the pump.
Attention!
Never store the motor in areas in which corrosive vapours exist.
3.2
Disassembly of pump FP 430 Ex S-41/38 FOOD for cleaning
> Pull out the inner tube
> Clean items or components with appropriate detergents.
> Observe internal operating instructions.
The assembly is done in reverse order
3.3
Disassembly of pump FP 427 S-43/38 FOOD for cleaning
> Unscrew the foot piece (1) (mind the left-hand thread).
> Unscrew the impeller (2) and push out the shaft (3) together with the coupling
cage and the ball bearing (4).
> To this end, use an appropriate screwdriver to hold the shaft (5).
> If the bearing detaches first, screw the impeller back onto the shaft and screw
the shaft back into the bearing a few turns.
> Give the impeller a light blow to push the bearing up and out; unscrew it and
pull it out of the inner tube.
> Pull the shaft out of the inner tube together with the impeller.
> Unscrew the impeller.
1
4
3
2
5