18 / 32
Original operating instructions battery motor type FBM-B 3100
ENGLI
SH
7.
Testing / Repair
Regularly check the pump according to the relevant national
safety regulations and/or rules for prevention of accidents (in the
Federal Republic of Germany these are e.g. DGUV V3).
Repairs should only be carried out by the manufacturer or an
authorized repair shop.
Before removing the motor empty pump, hose and valves.
7.1
Change of protection cover
The cover adheres strongly to the handle
.
To facilitate the assembly / disassembly,
the contact surfaces should be wetted with a few drops of detergent.
8.
Technical data
Pump
FP 314 ...
Material
PP/PVDF
PP
S
Ø outer tube / Ø rotor
25/19
32/25
28/25
Liquid temperature [°C]
0-45 (PP) 0-60 (PVDF)
0-60
Ambient temperature [°C]
0-40
Max. viscosity [mPas]
250
Motor
FBM-B 3100
Rotational speed
5.000-15.000
1/min
Motor type
BLDC
Nominal input power
100
W
Weight motor with battery and protective
cover
1,2
kg
Protection class with protective cover
IP44
Protection class without protective cover
IP40