Assembly of pump F 427 after cleaning
We recommend using the protective sleeve (10-961 40 122) for assembly.
> On F 427 S3A: Reinsert the PTFE seal.
> Push the bearings (1) into the inner tube and position them on the inner tube by
gently turning them.
> Screw the coupling cage with grooved ball bearing (2) onto the shaft (3) and tighten
it slightly.
> Screw the protective sleeve (4) onto the other end of the shaft.
> Push the shaft into the inner tube (5) and push it firmly into position.
> Slightly turn the bearings (6) to make sure that the shaft can easily be moved.
> Push the assembled inner tube into the outer tube.
> Push the lower bearing housing (7) over the protective sleeve into the outer tube
(by hand), so that it engages in the catches (8).
> Use an appropriate screwdriver to hold the shaft on the motor side (9).
> Unscrew the mounting tip.
> Screw the impeller (10) on.
> Screw the base piece (11) closed manually.
The pump is now ready to use.