![Flux F 425 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/flux/f-425/f-425_original-attachment_2310941015.webp)
Attachment Drum Pumps F 425, FP 425 Ex S and F 426
15 / 24
ENGLI
SH
4
Cleaning
> Pull the mains plug and shut off the compressed air, respectively, and disconnect
the supply.
> Loosen the union nut (connection between motor and pump).
> Take the motor off the pump.
Pump
Disassembly
FP 425 Ex S-41/34
F 426 S-41/38
With FP 425 Ex S and F 426 S:
> Loosen the adjusting lever and hexagon nut
> Remove the retaining element
F 425 PP-50/34
With F 425 PP:
> Push the retaining element outward
With F 425 PP, FP 425 Ex S, F 426:
> Turn the outer tube into position:
with F 425 lever position "valve OPEN" (see Fig. 5)
with F 426 lever position "mixing" (see Fig. 6)
> Pull out the inner tube
F 426 PP-50/33
> Unscrew the set screw (1)
> Pull out the inner tube (2)
> Push the retaining element
outward
> Turn the outer tube into
"mixing" position
> Pull the outer tube out of
the mixing tube
Assembly in reverse order.
Tightening torques F 425 / FP 425 Ex S / F 426
FP 425 Ex S-41/34
F 425 PP-50/34
F 426 S-41/38
F 426 PP-50/33
0.8 Nm
Only screw in slightly
5 Nm
Fig. 7: Tightening torques
2
1
Содержание F 425
Страница 24: ...FB 10 98000009_04 1019 0 5 DEF...