background image

VisiFault Instruction Sheet   8/16/2004  

English Page 

1 of 6 

Panel Size:  4-1/8" x 7" 

 

 

PN 2157599 May 2004  Rev. 1 8/04

 

 2004 Fluke Networks. All rights reserved. Printed in USA. 

All product names are trademarks of their respective companies. 

 

 
 

VisiFault

 

Visual Fault Locator 

Instruction Sheet 

The VisiFault Visual Fault Locator (VFL) is a visible light source 
that helps you trace optical fibers, check fiber continuity, and 
find faults such as breaks, bad splices, and tight bends in fiber 
optic cable.  

Safety Information 

W

*

Warning: Class 2 Laser

 

To avoid possible eye damage caused by hazardous 
radiation 

 

Never look directly into the VFL’s output (item 

A

 in 

Figure 1). Momentary exposure to the VFL’s output will 
not damage your eyes; however, direct, long-term 
exposure is potentially hazardous. 

 

Cover the VFL’s output with the dust cap when the VFL 
is not in use. 

 

Do not open the case (except to open the battery cover 
to change the batteries); no user-serviceable parts are 
inside. 

 

Do not modify the VFL. 

 

Do not magnify or otherwise modify the laser output. 
Use only approved connectors and adapters. 

 

Do not use controls, adjustments, or procedures not 
documented or approved by Fluke Networks. 

Содержание VisiFault Visual Fault Locator

Страница 1: ...le Safety Information W Warning Class 2 Laser To avoid possible eye damage caused by hazardous radiation Never look directly into the VFL s output item A in Figure 1 Momentary exposure to the VFL s output will not damage your eyes however direct long term exposure is potentially hazardous Cover the VFL s output with the dust cap when the VFL is not in use Do not open the case except to open the ba...

Страница 2: ...rs with 2 5 mm ferrules SC ST or FC For 1 25 mm ferrules use the optional 1 25 mm universal adapter 3 Press the key B to turn on the VFL 4 To toggle between continuous and flashing modes press the FLASH key C The status LED D indicates the VFL s output status 5 Turn off the VFL before disconnecting it from the fiber Replace the dust cap Tips View the VFL s light indirectly by holding a white card ...

Страница 3: ...ge 3 of 6 Panel Size 4 1 8 x 7 Continuity check tracing fibers Microbend or broken fiber Bad splice Sharp bend Broken fiber in connector VISUAL FAULT LOCATOR VISIFAULT CLASS II LASER FLASH 1 3 2 4 awx01f eps Figure 1 Using the Visual Fault Locator ...

Страница 4: ...del Number 2 5 mm to 1 25 mm universal adapter NF 380 Maintenance Clean the case with a soft cloth dampened with water or water and a mild soap Do not use abrasives solvents or alcohol If the VFL s light is dim or does not turn on replace the batteries as shown in Figure 2 awx03f eps Figure 2 Replacing the Batteries ...

Страница 5: ...a 82 2 539 6311 Singapore 65 6738 5655 Taiwan 886 2 227 83199 USA 1 800 283 5853 Visit our website for a complete list of phone numbers Specifications Laser type and classification 635 nm nominal laser diode Class 2 Fiber compatibility Multimode and singlemode Output port Universal adapter for connectors with 2 5 mm ferrules Output Continuous or flashing 2 Hz Output power 1 3 mW Range 3 km on mult...

Страница 6: ...nector tabs cable insulation displacement connectors or damage from accident neglect misuse alteration contamination or abnormal conditions of operation or handling Resellers are not authorized to extend any other warranty on Fluke Networks behalf To obtain service during the warranty period contact your nearest Fluke Networks authorized service center to obtain return authorization information th...

Отзывы: