3-4
VIBXPER
T II Balancing 12.2019
Appendix
Emergency storage
If the balancing procedure is stopped prematurely (e.g. battery dis-
charged), the data are stored in a recovery file. When the device is
switched on again, the balancing procedure can be continued with the
aid of this recovery file.
Opening the recovery file
• Switch on the measuring device.
• In the start screen, click on the 'Balance' symbol.
• Open the tab in which the interrupted balancing procedure was
started (e.g. '1 plane').
The recovery file is labeled with a warning symbol.
• Click on the recovery file to open the recovery dialog box. It shows
information on when the emergency storage took place and the
number of balancing steps (see below).
• Click on 'Restore' to open the file and continue the balancing proce-
dure, or to save the data properly.
Click on 'Discard' to clear the data in the recovery file and start a
new measurement.
Use 'Exit' to leave the recovery dialog box without deleting the re-
covery file.
Continuing the balancing procedure
after emergency storage