Maintenance

Line Monitoring

W

Caution

When testing circuits which are relatively 
close to the battery source, the clicks may be 
loud enough to cause acoustical shock if the 
receiver is held tightly against the ear. 

The TS22 Series Test Sets are designed to 
rest comfortably on the shoulder with the 
receiver away from the ear. They should be 
used in this position when listening for 
clicks.

Set the TALK/MONITOR switch to M and connect test 
leads to circuit under test. Monitoring may now be 
done without disrupting traffic. The high impedance of 
the TS22A Test Set prevents the spiking of data traffic.

Troubleshooting

The following troubleshooting procedures are based 
largely on the click heard when the two test leads on 
are placed on battery and ground, or across a charged 
capacitor. These clicks and other sounds from the 
receiver can help you locate open circuits, shorts, 
crosses, and grounds:

1

To locate a short circuit, open one side of the line 
and place the TS22 or TS22A Test Set in the loop – 
one test lead to each side of the opened line. On 
the Central Office (CO) side of the fault, a loud 
CLICK will be heard; on the field side of the fault, 
NO CLICK will be heard. The TS22 and TS22A Test 
Sets should be in the Monitor mode (with or 
without the amplified speaker on).

2

Locating an open circuit is accomplished by 
bridging the TS22 or TS22A Test Sets across the 
circuit – one test lead on Tip, the other on Ring. 
Moving away from the CO, the fault is located at 
the point the loud CLICK disappears.

3

Continuity of each side of the loop may be verified 
by placing one of the line leads on a local ground 
and the other on the conductor in question. On a 
good Ring conductor, a CLICK will be heard; on a 
good Tip conductor, an inductive HUM will be 
heard (due to the difference in ground potential 
between the CO ground and the local ground).

Maintenance

WX

Warning

Disconnect clips from any metallic 
connections before performing any 
maintenance. Read all instructions 
completely and understand possible hazards 
to end user if repairs are not performed 
properly.

Batteries are hazardous to handle. Do not 
allow the terminals to be shorted together. 
Severe burns or explosion can result if not 
handled properly. Dispose of battery 
properly to ensure contacts cannot short. 
Disposal may be restricted by local laws.

W

Caution

Do not use CRC Cable Clean

®

 or any similar 

chlorinated solvent on the test set. Doing so 
will damage the test set.

Replacing the Battery

W

Warning

When not in use, the 9 V battery in the TS22 
Series Test Sets should be changed once a 
year to prevent the 3 V lithium battery from 
draining.

W

Warning

When your 9 V battery is low your 
speakerphone will no longer work. You 
should replace your 9 V battery with a new 
battery immediately as to not drain the 3 V 
lithium battery.

Содержание TS 19

Страница 1: ...TS 22 Series Craft Test Sets Users Guide PN 2451689 October 2005 2005 Fluke Corporation All rights reserved Printed in China All product names are trademarks of their respective companies ...

Страница 2: ...r or replacement of a defective product which is returned to a Fluke Networks authorized service center within the warranty period To obtain warranty service contact your nearest Fluke Networks authorized service center to obtain return authorization information then send the product to that service center with a description of the difficulty postage and insurance prepaid FOB destination Fluke Net...

Страница 3: ...ker Monitor Modes 5 Keypad Controls and Indicators 6 Operation 7 TS22 Amplified Speaker Mode 7 TS22A Speakerphone Mode 7 TS22A Speaker Monitor Mode 7 Selecting a Dial Signal 7 Last Number Redial 7 Storing Number in Repertory Memory Auto Dialer 8 Storing a Number When On Hook Or Disconnected Preferred Method 8 Storing a Number You are Calling 8 Putting a Pause in a Stored Number 8 Dialing a Stored ...

Страница 4: ...TS22 Series Craft Test Sets Users Guide ii ...

Страница 5: ...sonnel for line testing and temporary communications Specifications herein apply to TS22 and TS22A models unless otherwise noted Registration Registering your product with Fluke Networks gives you access to valuable information on product updates troubleshooting tips and other support services To register fill out the online registration form on the Fluke Networks website at www flukenetworks com ...

Страница 6: ...he line cord the test set or both Increase separation between the source of the interference and the test set Try connecting to another working pair Physical Characteristics Housing See Figure 1 The housing for the TS22 Series Test Set is made of high impact polycarbonate which provides excellent insulating properties The test set is designed to provide rugged service and withstand the rough handl...

Страница 7: ...set The TS22A speakerphone operates from line voltage in the TALK mode only When the speaker fails to operate at all operates intermittently or sounds distorted replace the 9 V battery with a similar battery See Replacing the Battery on page 9 for instructions on changing the battery Note If the test set fails to operate properly at any time first replace the battery and retest before sending the ...

Страница 8: ... high Note When the speaker is on the polarity LEDs go out They will turn back on when the speaker timer elapses or is turned off via the SPEAKER button When the speaker is on the transmitter and receiver are automatically switched off to prevent acoustic feedback With no signal present the speaker will automatically turn off after 5 minutes to conserve battery power Any signal greater than a nomi...

Страница 9: ...e regular transmitter and receiver to prevent acoustic feedback from the speaker The polarity LEDs turn off when the TS22A unit is switched from Talk mode to either the speakerphone mode or the speaker mode To prolong battery life the TS22A Test Set will automatically shut off the speakerphone or speaker after approximately five minutes when there has been no signal greater than 30 dBm Because of ...

Страница 10: ...ulse modes PSE Key The PSE Pause key places a four second pause between numbers that are being entered into repertory memory The pause will take place when the stored numbers are redialed and is used to access second dial tone when dialing through a PBX Tone Pulse Switch In MONITOR mode this switch turns off the ringer In TALK mode this switch selects TONE or PULSE dialing mode Polarity Light Emit...

Страница 11: ...the TALK MONITOR switch to M then press the SPEAKER button once to enter speaker mode with low volume 2 Press the SPEAKER button a second and third time for medium and high volume 3 Press the SPEAKER button a fourth time for off and return to Monitor mode Selecting a Dial Signal Select the type of dial signaling required DTMF or dial pulse with the TONE PULSE switch 1 Set the TALK MONITOR switch t...

Страница 12: ...he number key for the chosen memory location 1 9 Storing a Number You are Calling 1 Connect the test set to the line and receive dial tone 2 Dial the number Note In the Pulse mode pressing STO will stop any further digits from being outpulsed although all digits will be stored Therefore wait until all digits have been outpulsed before pressing STO 3 Press the STORE PROG key 4 Press one of the numb...

Страница 13: ...en circuit is accomplished by bridging the TS22 or TS22A Test Sets across the circuit one test lead on Tip the other on Ring Moving away from the CO the fault is located at the point the loud CLICK disappears 3 Continuity of each side of the loop may be verified by placing one of the line leads on a local ground and the other on the conductor in question On a good Ring conductor a CLICK will be he...

Страница 14: ...um 9 V battery 7 Replace the battery boot retainer cover and screws Strain relief ring must be inside the case as shown Avoid pinching battery wires bfs06 eps Figure 5 Battery Replacement Replacing the Belt Clip See Figure 6 The belt clip assembly is field replaceable in the event of damage or prolonged wear To order a replacement belt clip contact your local Fluke Networks authorized distributor ...

Страница 15: ...urce 9 V battery provides 25 hours continuous use typical Speaker Levels for TS22 Low medium high and off Automatic Power Shut Off After 5 min of no audio signal Speakerphone Levels TS22A Low medium high and off Power Source Shared line and battery power Physical Measurement 10 25 in x 2 69 in x 3 38 in 26 cm x 6 83 cm x 8 57 cm Weight TS22 21 ounces 595 kg TS22A 22 ounces 624 kg typical Environme...

Страница 16: ...12 TS22 Series Craft Test Sets Users Guide ...

Отзывы: