background image

Thermal imaging  

terminology explained

Palette—

Color representation of the 

temperatures (temperature scale) in a displayed 

image. Certain color palettes meet personal 

preferences or optimize the image for different 

applications and/or problems. An example of the 

different palettes appear to the right.

Sensor Size—

Similar to digital cameras the 

sensor size describes the amount of displayed 

points per image of a thermal imager. A sensor 

size of 160 x 120 captures and displays more 

than 19,000 measurement points with each 

measurement. If the imager is fully radiometric 

then it also truly measures and stores all 

captured points with the image.

Field of view (FOV)—

Indicates what the 

thermal imager sees or measures at a given 

moment. The combination of the Field Of View 

specification and the distance to the measured 

object determines which surface or part of an 

object will be measured as a total. A thermal 

imager with a FOV of 23° x 17° (20 m), F=0.8 

lens) can detect an object that is 6 m (20 ft) 

wide by 4.5 m(15 ft) high. This same imager can 

infer a temperature measurement of a smaller 

section within that object of 3.8 cm X 3.8 cm 

(1.5 in x 1.5 in). A FOV calculator on www.fluke.

com/FOV helps you calculate the measurement 

surface at various distances to the object.

Thermal sensitivity   —

Indicates what the 

smallest temperature difference is which can 

be measured/displayed in an image. It basically 

is the maximum resolution of the image and 

is referred to as NETD (noise equivalent 

temperature difference). 

Emissivity adjustment—

All surfaces emit 

infrared energy or heat. The level of emission 

varies much per surface and is described 

with the term emissivity. Painted coatings 

and materials usually have a high emissivity 

while polished aluminum has a low emissivity. 

Visit www.fluke.com/emissivity for a table 

with emissivities for different materials. If you 

perform qualitative inspections with the imager 

(most applications) then emissivity does not 

have to be adjusted. To measure the temperature 

of a material accurately it will be necessary to 

adjust for the material’s emissivity in specific 

applications.

Span—

The set of temperature values that can be 

measured within a preset range. Adjusting the 

span allows you to see more subtle temperature 

gradients (or contrast) in a captured image. 

When the span is optimized the imager shows 

256 different shades of color in an image.

Ironbow

Blue-red

High contrast

Amber

Hot metal

Grey

9

8

9

8

Содержание TiR

Страница 1: ... images fused together makes infrared easy to understand Designed especially for building and restoration applications Rugged reliable easy to use what Fluke tools reputation has been for over 50 years Models for any application and budget Fluke TiR Series Thermal Imagers ...

Страница 2: ...reas such as Moisture intrusion in roof systems walls flooring ceilings and other building areas Leaks in water pipes buried steam lines water lines or underground heating systems and sprinkler systems Missing or inadequate insulation areas Heat or cooling loss HVAC R problem areas Connection problems in low voltage electrical systems Termite and pest issues Construction failure areas Moisture det...

Страница 3: ... menu options give you access the different blending options from full thermal image to full visual image Automatic blend provides enhanced detail to help locate problems precisely along with a visual frame of reference and helps to better focus the image See things both ways Infrared and visual visible light images fused together communicating critical information faster and easier traditional in...

Страница 4: ...become visible with the large widescreen full color LCD display Intuitive three button menu is easy to use simply navigate with the push of a thumb No need to carry pen and paper record findings by speaking into the camera voice annotation comments are saved with the image TiR1 only Store more than 3 000 screen images bmp format or 1 200 IR Fusion images on included 2 GB SD memory card Optimized f...

Страница 5: ... Exportable to JPEG BMP GIF PNG TIFF WMF EXIF and EMF Voice memo recorder voice annotation Yes No Software Controls and adjustments Software SmartView Full analysis and reporting software included Set up controls Date time C F language emissivity hot spot and cold spot on image Date time C F language Language selection English German French Spanish Portuguese Italian Swedish Finnish Russian Czech ...

Страница 6: ...d problem detection and analysis capabilities with patent pending IR Fusion Technology only available from Fluke View crisp clear images on large LCD screen Industry leading thermal sensitivity 0 05 C NETD on TiR4FT 0 07 C NETD on TiR3FT and TiR2FT provides solid resolution and ultra high quality images Easily view around obstructions with the 180 articulating lens Exceptional image resolution del...

Страница 7: ...atial resolution IFOV 2 45 mrad 4 9 mrad Minimum focus distance 0 3 m Image and data storage Storage medium Compact flash card stores more than 1000 IR images 512 MB card standard File formats supported 14 bit measurement data included Exportable BMP GIF JPEG PNG TIFF Interfaces and software Interface Compact flash card reader included Software SmartView full analysis and reporting software includ...

Страница 8: ...3 8 cm X 3 8 cm 1 5 in x 1 5 in A FOV calculator on www fluke com FOV helps you calculate the measurement surface at various distances to the object Thermal sensitivity Indicates what the smallest temperature difference is which can be measured displayed in an image It basically is the maximum resolution of the image and is referred to as NETD noise equivalent temperature difference Emissivity adj...

Страница 9: ...lection to enhance contrast or display detail more effectively Unlimited standard and user defined analysis markers Five viewing modes allows you to choose the best image presentation for your application needs Simplified report generation Generate professional customized reports fast One click standardized report generation for a quick results Choice of features including Before after IR plus vis...

Страница 10: ... 2675 200 or Fax 31 0 40 2675 222 In Canada 800 36 FLUKE or Fax 905 890 6866 From other countries 1 425 446 5500 or Fax 1 425 446 5116 Web access http www fluke com 2007 Fluke Corporation Specifications subject to change without notice Printed in U S A 10 2007 2694792 B EN N Rev B Electrical and industrial professionals all over the globe have been reaching for Fluke tools for over 50 years con fi...

Отзывы: