background image

Locate building 

problems quickly 

and easily

Fluke TiR Series Thermal Imagers are built 

specifically for the building diagnostic industry. 

Property managers

 and 

facility managers

 

use thermal imaging to protect investments 

and keep buildings in a well maintained, 

healthy state.

Restoration professionals

 are using 

thermal imaging to increase their business, 

differentiate themselves from their competitors 

and generate documentation in case they need 

to defend a future liability claim.

Typical thermal imaging 

building applications:

Thermal imaging is an efficient, non- 

destructive testing method to detect  

(potential) problem areas such as:

  Moisture intrusion in roof systems, walls, 

flooring, ceilings and other building areas

  Leaks in water pipes, buried steam lines, 

water lines or underground heating  

systems and sprinkler systems

  Missing or inadequate insulation areas

  Heat or cooling loss, HVAC/R  

problem areas

  Connection problems in low voltage  

electrical systems

  Termite and pest issues

  Construction failure areas

Moisture detection: 

Accurately detect 

moisture behind interior walls, in ceilings, 

and under carpets.

Mold remediation: 

Control mold by 

revealing undetected sources of moisture 

Roofing: 

Detect water-saturated 

insulation in flat-roof systems to locate 

damaged portions of roofing structure.

Energy audits: 

Perform residential and 

commercial energy audits by scanning for 

heating or cooling (energy) loss, moisture 

invasion, and HVAC/R problems.

2

3

Содержание TiR

Страница 1: ... images fused together makes infrared easy to understand Designed especially for building and restoration applications Rugged reliable easy to use what Fluke tools reputation has been for over 50 years Models for any application and budget Fluke TiR Series Thermal Imagers ...

Страница 2: ...reas such as Moisture intrusion in roof systems walls flooring ceilings and other building areas Leaks in water pipes buried steam lines water lines or underground heating systems and sprinkler systems Missing or inadequate insulation areas Heat or cooling loss HVAC R problem areas Connection problems in low voltage electrical systems Termite and pest issues Construction failure areas Moisture det...

Страница 3: ... menu options give you access the different blending options from full thermal image to full visual image Automatic blend provides enhanced detail to help locate problems precisely along with a visual frame of reference and helps to better focus the image See things both ways Infrared and visual visible light images fused together communicating critical information faster and easier traditional in...

Страница 4: ...become visible with the large widescreen full color LCD display Intuitive three button menu is easy to use simply navigate with the push of a thumb No need to carry pen and paper record findings by speaking into the camera voice annotation comments are saved with the image TiR1 only Store more than 3 000 screen images bmp format or 1 200 IR Fusion images on included 2 GB SD memory card Optimized f...

Страница 5: ... Exportable to JPEG BMP GIF PNG TIFF WMF EXIF and EMF Voice memo recorder voice annotation Yes No Software Controls and adjustments Software SmartView Full analysis and reporting software included Set up controls Date time C F language emissivity hot spot and cold spot on image Date time C F language Language selection English German French Spanish Portuguese Italian Swedish Finnish Russian Czech ...

Страница 6: ...d problem detection and analysis capabilities with patent pending IR Fusion Technology only available from Fluke View crisp clear images on large LCD screen Industry leading thermal sensitivity 0 05 C NETD on TiR4FT 0 07 C NETD on TiR3FT and TiR2FT provides solid resolution and ultra high quality images Easily view around obstructions with the 180 articulating lens Exceptional image resolution del...

Страница 7: ...atial resolution IFOV 2 45 mrad 4 9 mrad Minimum focus distance 0 3 m Image and data storage Storage medium Compact flash card stores more than 1000 IR images 512 MB card standard File formats supported 14 bit measurement data included Exportable BMP GIF JPEG PNG TIFF Interfaces and software Interface Compact flash card reader included Software SmartView full analysis and reporting software includ...

Страница 8: ...3 8 cm X 3 8 cm 1 5 in x 1 5 in A FOV calculator on www fluke com FOV helps you calculate the measurement surface at various distances to the object Thermal sensitivity Indicates what the smallest temperature difference is which can be measured displayed in an image It basically is the maximum resolution of the image and is referred to as NETD noise equivalent temperature difference Emissivity adj...

Страница 9: ...lection to enhance contrast or display detail more effectively Unlimited standard and user defined analysis markers Five viewing modes allows you to choose the best image presentation for your application needs Simplified report generation Generate professional customized reports fast One click standardized report generation for a quick results Choice of features including Before after IR plus vis...

Страница 10: ... 2675 200 or Fax 31 0 40 2675 222 In Canada 800 36 FLUKE or Fax 905 890 6866 From other countries 1 425 446 5500 or Fax 1 425 446 5116 Web access http www fluke com 2007 Fluke Corporation Specifications subject to change without notice Printed in U S A 10 2007 2694792 B EN N Rev B Electrical and industrial professionals all over the globe have been reaching for Fluke tools for over 50 years con fi...

Отзывы: