Installation
Model 2-Wire
37
5
Step 4
Put the following on the cable: the PG nut (1) and the relief
bushing (2).
Step 5
Prepare the cable. Remove about 6 cm (2.36 in) of the
insulation.
Shorten the shield to about 1 cm (0.4 in).
Tin-coat the connecting leads if not done yet.
Step 6
Feed the prepared cable with the metal cone ring.
Step 7
Make sure to have a proper contact between the braided
shield and the metal cone ring.