CONNECTION INSTRUCTIONS
Two typical daisy-chain addressing installations are described.
INDIVIDUAL SWITCH ADDRESSING
1. For a single Server or PC installation, use a DRL460-6-6 control Y-cable to connect the DB9
male lead (labeled
A
) to the
COM 1
port of the server or PC as shown below in
Figure 12
.
For single server installations, the DB9 male lead (labeled
B
) has been factory tie-wrapped
into a two-inch coil — approximately eight inches from the tap connector — so it can be
easily stored either above, below or hang behind the Fluke Networks switch.
Figure 12. Connectivity diagram for individual daisy-chain addressing
2. Connect the miniature 4-pin male quick lock power supply connector into the
POWER
port of
the TAP-100-2X16 and then plug the power supply into the external power source wall receptacle.
The model number and switch status will scroll on the front display.
3. Set the address of each individual switch using the SET SWITCH ADDRESS function as described in
the control pull-down menu section of the Fluke Networks MANagents software guide.
14
Daisy-Chain Addressing
B
A