Fluke PLS 3X360G Скачать руководство пользователя страница 21

17

3X360R, 3X360G 

Specifications

Specifications

Specifications

PLS 3X360R

PLS 3X360G

Battery (RBP5)

Lithium-ion, 3.6 V, 5200 mAh

Battery Life, 

 

Continuous Use (typical)

3 beams: ≥ 9 hours

 

1 beam: ≤ 30 hours

3 beams: ≥ 5 hours

 

1 beam: ≤ 17 hours

Line Fan Angle

Horizontal

360°

Front Vertical

360°

Side Vertical

360°

Working Range

Without line detector

65 ft (20 m)

115 ft (35 m)

With line detector

165 ft (50 m)

210 ft (65 m)

Accuracy

± 5/64 in @ 33 ft (± 2 mm @ 10 m)

Laser Leveling

System

Automatic Pendulum

Range

Self-leveling: ≤ 4°

Out of self-levelling: > 6°

Leveling time

≤ 3 sec

Temperature

Operating

14 °F to 122 °F (-10 °C to 50 °C)

Storage

With Battery: -4 °F to 122 °F (-20 °C to 50 °C)

Without Battery: -13 °F to 158 °F (-25 °C to 70 °C)

Relative Humidity

0 % RH to 90 % RH (0 °C to 35 °C) 

0 % RH to 75 % RH (35 °C to 40 °C) 

0 % RH to 45 % RH (40 °C to 50 °C)

IP rating

IP 54

Drop test

3.28 ft (1 m)

Battery status indication 

100%, 75%, 50%, 25% and low battery

Size (H x W x L) w/ RBP5

5.12 in x 3.58 in x 5.25 in (13 cm x 9.09 cm x 13.33 cm)

Weight (with battery)

1.76 lbs (0.8 kg)

Li-ion battery safety

IEC 62133

Laser Safety

Class 2 (IEC 60825-1)

Light Source

Semiconduction laser diode

Max Output Power

< 1 mW

Wavelength

Red

635 nm ± 10 nm

Green

520 nm ± 10 nm

Electromagnetic Compatibility (EMC)

International

IEC 61326-1

Korea (KCC) 

Class A Equipment (Industrial Broadcasting & Communication Equipment) 

[1]

[1]

 This product meets requirements for industrial (Class A) electromagnetic wave 

equipment and the seller or user should take notice of it. This equipment is intended for 

use in business environments and is not to be used in homes.

USA (FCC) 47 

47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.

Содержание PLS 3X360G

Страница 1: ...3X360G Three Plane Lasers Users Manual 09 2020 2020 Fluke Corporation All rights reserved Specifications are subject to change without notice All product names are trademarks of their respective comp...

Страница 2: ...nter to obtain return authorization information then send the product to that Service Center with a description of the problem THIS WARRANTY IS YOUR ONLY REMEDY NO OTHER WARRANTIES SUCH AS FITNESS FOR...

Страница 3: ...3 Lasers and Optical Glass 4 Controls 5 Check Product Accuracy 6 Cone Accuracy 6 Horizontal Leveling Accuracy 8 Vertical Accuracy 10 90 Degree Accuracy 12 Accessories 14 3X360 Magnetic L bracket 14 Ma...

Страница 4: ...ii 3X360R 3X360G Users Manual...

Страница 5: ...lly read all instructions Do not alter the Product and use only as specified or the protection supplied by the Product can be compromised Do not use the Product if it operates incorrectly Do not use t...

Страница 6: ...e Annex I this product is classed as category 9 Monitoring and Control Instrumentation product Do not dispose of this product as unsorted municipal waste Indicates a Class 2 laser DO NOT STARE INTO BE...

Страница 7: ...f your Product Table 2 Features 1 2 4 3 5 A Fluke Compa ny 44mm 1 71 In 61mm 2 4 In In 2 2 1 0 5 0 5 1 1 5 2 3 3 4 5 1 1cm Item Description 3X360R 3X360G Z 3X360R 3X360G KIT 1 The Product 2 Rechargeab...

Страница 8: ...the lasers and optical glass Table 3 Lasers and Optical Glass 5 6 4 3 2 1 Item Description Item Description 1 Front vertical 360 line laser 4 Housing glass insert 2 Side vertical 360 line laser 5 Tow...

Страница 9: ...cal laser button Turns on or off the side vertical laser 7 Pendulum lock Slides to lock or unlock the lasers 8 Pendulum unlock position The self leveling feature keeps the lasers visible when the Prod...

Страница 10: ...n one direction 2 Turn on the horizontal beam and project on the parallel wall You will need to have a set distance between a b which will be referred to as D with the horizontal beam D a b a is 3 2ft...

Страница 11: ...Accuracy a b c E c a illustration 3 5 Mark c directly above or below a 6 Measure the distance between these two marks a c If the measurement value is greater then the corresponding E value take to yo...

Страница 12: ...or the specific use case and is illustrated in Table 6 1 Place the laser on a flat surface going in one direction You will need to have a set distance between a b which will be referred to as D 2 Turn...

Страница 13: ...d b and this is E b d a E d b Rotate 180 Horizontally illustration 3 7 Rotate the laser 270 degrees horizontally as seen below 8 Mark e and calculate the distance between e b and this is G 9 If any o...

Страница 14: ...1 16 in 16 4 ft 5 64 in 32 8 ft 5 32 in It is important to conduct an accuracy check at the expected working distance for the specific use case and is illustrated in Table 7 1 Place the laser on a fl...

Страница 15: ...n position the vertical beams with existing a b marks These marks on the ground become e f 4 On the ceiling mark two short lines g h b h d e f c g a K d h L g c illustration 3 5 Measure the distance b...

Страница 16: ...ooth flat and stable surface that is level in both directions 2 Turn on the side vertical beam 3 Mark the center of the beam at three locations on the ground as seen below at a b c and b should be the...

Страница 17: ...ion the front and side vertical beams with b 9 Mark e and measure the distance D beweetn c e 10 If the value is greater than D values take to your service provider D b a c d e b e c Rotate 90 Horizont...

Страница 18: ...S RRT4 Red magnetic reflective target 5022629 PLS GRT4 Green magnetic reflective target 5022634 Note PLS 3X360 is not compatible with PLS BP5 alkaline battery pack PN 5031952 3X360 Magnetic L bracket...

Страница 19: ...Clean the Product Clean the case with a damp cloth and a weak soap solution Caution To prevent damage to the Product do not use abrasives isopropyl alcohol or solvents to clean the case or optic windo...

Страница 20: ...ass is damaged replace the housing glass insert See Table 6 for the part number to order for your Product To replace the housing glass insert see Figure 4 1 Remove the four housing glass insert screws...

Страница 21: ...0 C to 35 C 0 RH to 75 RH 35 C to 40 C 0 RH to 45 RH 40 C to 50 C IP rating IP 54 Drop test 3 28 ft 1 m Battery status indication 100 75 50 25 and low battery Size H x W x L w RBP5 5 12 in x 3 58 in x...

Отзывы: