6
3X360R, 3X360G
Users Manual
Check Product Accuracy
Cone Accuracy
Table 5
D
Laser to a is 1m
E
3 m
≤ 1.6 mm
4 m
≤ 2 mm
5 m
≤ 2.4 mm
9 m
≤ 4 mm
D
Laser to a is 3.2 ft
E
9.8 ft
≤ 1/16 in
13.1 ft
≤ 5/64 in
16.4 ft
≤ 3/32 in
29.5 ft
≤ 5/32 in
1. Place the laser on a flat surface going in one direction.
2.
Turn on the horizontal beam
and project on the parallel wall. You will need to have a set distance between (a,b)
which will be referred to as "D" with the horizontal beam.
D
a
b
a
is 3.2ft (1m) away from laser
illustration 1
b
a
b
Rotate 180° Horizontally
illustration 2
3. Rotate the laser 180 degrees horizontally and place at point b, as seen above .
4. Turn on the horizontal beam
and adjust the laser height so the center of the beam is aligned with mark b.
Содержание PLS 3X360G