How to Use the Toner
1
For unterminated cable, connect the
correct adapter to an ID cap or the toner
cap, then connect the cap to the far end of
the cable.
2
Connect the correct adapter to the main unit.
3
Turn on the main unit, then connect it to
the near end of the cable.
4
The LED on the main unit shows the results:
Off:
The circuit is open.
Red:
The circuit is shorted.
Green. The main unit emits a loud,
steady tone:
The circuit has continuity to
the toner cap or to a 50
or 75
terminator. If the toner cap is connected,
it also emits a loud, steady tone.
Note
If the condition of the line changes,
the main unit emits a loud, brief tone.