NORMA 6003/NORMA 6003+/
NORMA 6004/NORMA 6004+
User Manual
62
Data Management
The Analyzer can save the measurement data and the current configuration of the Analyzer in the
internal memory, or log the data displayed on the current screen in Meter mode for a long time. The
data can be downloaded to a PC by using the Fluke Power Analyzer software. For more information,
please refer to the instructions for using the PC software.
Use
(
Memory
) to manage the data stored in the internal memory.
Save Data
On any measurement screen, push
(
Save
) and the Save dialog box will show on the
screen.
Push
A
(
Data
) to save all valid measurements at the current time to the internal memory. When it
is saved successfully, a prompt message containing the name of the file will show on the screen.
Push
B
(
Settings
) to save the current system settings and the configuration of all measurement
functions. When the save is successful, a message containing the name of the file shows on the
screen.
Note
The Analyzer automatically creates the file name based on the category of the saved
data and system time. To modify the file name, after it is saved, push
(Memory) and follow the prompt. (See
Logger
In Meter mode, push and hold
(
Save
) for more than 2 seconds, to show the Logger menu
on the screen. Then push
A
(
Start Logger
) to manually start the logger.
The Analyzer will log all measurements currently shown on the screen in the Meter mode.
During logging, the user cannot switch screens and perform other measurement functions. If the user
tries to perform other operations, a message will appear on the screen: "Please stop logger first!".
To stop logging, push
B
(
Stop Logger
) in the logger interface, and the screen will prompt you
that create log file successfully, including the name of the log file.
Note
The logger function is available in the Meter mode only. In other modes, when you
push and hold
(Save), the Analyzer will show a message that indicates the
Logger is only available in Meter mode.
Note
Even in Meter mode, the logger function is not supported if the user freezes the display
with the
(Hold) button. You must exit the Hold mode first before you can use
the Logger function.