14
Inclination Angle
Measuring range..................-90° to +90°
Resolution ..............................0.1°
Measuring Accuracy...........±1.5° @ -50° to +50°
±2.5° @ -85° to -50° and +50° to +85°
±3.5° @ -90° to -85° and +85° to +90°
Note
Inclination accuracy is specified as the angle between a
vertical and the absolute horizontal plane/true horizontal
baseline. The Product is calibrated to true horizontal 0
°.
Compass
Measuring Range.................0° to 360°
Resolution ..............................1°
Measuring Accuracy...........±7°
Note
Measurements valid for device inclination between -20°
and +20° to horizontal. Outside that range,
---
shows on
the LCD. Result is in reference to magnetic north.
Memory
Type .........................................EEPROM
Size (kB/records)..................64 kB/6400
Recording Time ....................up to 17 hours
RTC.................................................Yes (super CAP supply)
Communication .........................LBT: only with SMFT models
Size.................................................150 mm x 80 mm x 35 mm
(5.90 in x 3.14 in x 1.37 in)
Weight...........................................231g (0.5 lb)
Power Supply and Battery Life
Batteries .................................4x AA IEC LR6
Battery Life (typical)............50 hours
Temperature
Operating
IRR2-BT .............................-20 °C to 35 °C, 95 % RH
35 °C to 50 °C, 40 % RH
80PR-IRR...........................-30 °C to 100 °C
Storage ...................................-30 °C to 60 °C (humidity <80 %)
Altitude .........................................2000 m maximum
Ingress Protection ....................IEC 60529: IP40