13
Product Disposal
Dispose of the Product in a professional and environmentally
appropriate manner:
Delete personal data on the Product before disposal.
Remove batteries that are not integrated into the electrical
system before disposal and dispose of batteries separately.
If this Product has an integral battery, put the entire Product in
the electrical waste.
Cleaning
Periodically wipe the case with a damp cloth and mild detergent.
W
Caution
To prevent damage to the Meter:
The Product contains no user-serviceable parts. To
avoid injury, or damage to the Meter, do not open the
case.
To avoid damaging the Product, do not use abrasives
or solvents to clean the Product case.
Storage
During long periods of non-use (>60 days), remove the battery
and store separately from the Product.
Service and Parts
Only a qualified technician should service the Product. For service
information, contact your nearest Fluke dealer or service center.
Specifications
Irradiance
Measuring range..................100 to 1400 W/m²
Note
Calibration is performed at a solar spectral irradiance of
AM1.5 (ASTM G-173).
Resolution ..............................1 W/m²
Measuring Accuracy...........±(5 % + 5 Digit)
Temperature Measurement
Measuring range (°C)..........-30 °C to 100 °C (-22 °F to 212 °F)
Resolution ..............................0.1 °C (0.2 °F / 1 °F @ >100 °F)
Measuring Accuracy...........±1 °C (±2 °F) @ -10 °C to 75 °C
(14 °F to 167 °F),
±2 °C (±4 °F) @ -30 °C to -10 °C
(-22 °F to 14 °F) and 75 °C to 100 °C
(167 °F to 212 °F)
Note
Temperature measurement response time: ~30 sec.