![Fluke i50s Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/fluke/i50s/i50s_user-manual_2310246017.webp)
Current Probe
Specifications
13
Specifications
Probe
The following lists the Probe specifications.
Electrical Specifications
Nominal current
In ± 30 A dc or A rms
Measuring range
I max ±50 A pk (duration <10 sec)
Output voltage Vo
Low range 1 V/A
1 M
Ω
High range 100 mV/A
1 M
Ω
Overall accuracy (dc to 100 Hz at 25
°
C)
± 0.5 % at IN typical
± 1.5 % at IN max
Gain variation (max)
± 0.04 % of rdg/
°
C
Step response
see Figure 5
Frequency response
see Figure 6
Insertion impedance ZI
see Figure 7
< 0.1
Ω
up to 10 MHz
< 0.4
Ω
10 MHz to 50 MHz
External magnetic field rejection rate
60 dB (ac and dc)
Rejection rate of fast dV/dt at 5 kV/
μ
s
< 15 m AT (during dV/dt)
Output noise level (rms)
1 m AT rms typical
(measured with a filter at 25 MHz)
Output noise level (pk to pk)
9 mAT pp
(measured with a filter at 25 MHz)
Содержание i50s