Maintenance
47
Maintenance
Follow the maintenance procedures given in the
DTX
Series CableAnalyzer Users Manual
.
Clean the optical connectors as described on page 10.
Replacing Fiber Reference Test Cords
Choose replacement fiber optic reference test cords that
meet the following requirements:
•
Core and cladding size: match the fiber to be tested
•
Connector polish: PC or UPC
•
Reference test cord length: maximum 5 m
To ensure optimum performance from your tester, get
replacement reference test cords from Fluke Networks.
Using the Smart Remote with an
OptiFiber
Certifying OTDR
You can use a DTX Series smart remote with a
DTX-MFM2 or DTX-SFM2 fiber module as the remote for
a Fluke Networks OptiFiber Certifying OTDR. The DTX
remote takes the place of a second OptiFiber tester for
measuring loss and length with the OptiFiber loss/length
option in Smart Remote mode. You can buy a smart
remote separately for this purpose. See the Fluke
Networks website or contact Fluke Networks for details.
Содержание DTX-GFM2
Страница 15: ...Installing the Connector Adapter 9 amd99f eps Figure 4 Installing the Connector Adapter...
Страница 29: ...Certifying Fiber Cabling 23 amd145f eps Figure 8 Smart Remote Mode Reference Connections Method B...
Страница 31: ...Certifying Fiber Cabling 25 amd146f eps Figure 9 Smart Remote Mode Test Connections Method B...
Страница 35: ...Certifying Fiber Cabling 29 amd147f eps Figure 11 Loopback Mode Reference Connections Method B...
Страница 37: ...Certifying Fiber Cabling 31 amd148f eps Figure 12 Loopback Mode Test Connections Method B...
Страница 41: ...Certifying Fiber Cabling 35 amd149f eps Figure 14 Far End Source Mode Reference Connections Method B...
Страница 45: ...Using the Visual Fault Locator 39 amd23f eps Figure 17 Using the Visual Fault Locator...
Страница 48: ...DTX MFM2 GFM2 SFM2 Fiber Modules Users Manual 42 amd58f eps Figure 19 Connections for Monitoring Optical Power...
Страница 60: ...DTX MFM2 GFM2 SFM2 Fiber Modules Users Manual B 4...