Maintenance and Service

Clean the adapters with a soft cloth that is moist with water or water and 
a mild soap. Do not use abrasives, solvents, or alcohol.

If an adapter does not operate correctly, look for damage to the adapter’s 
connectors. Make sure that the adapter is latched tightly to the tester.

The adapters have no serviceable parts. To get a replacement adapter, 
speak to a Fluke Networks representative. 

For the most current test limits and features, keep your tester’s firmware 
current. The latest version of firmware is available at no charge on the 
Fluke Networks website.

Contact Fluke Networks

»

www.flukenetworks.com/support

[email protected]

1-800-283-5853, +1-425-446-5500

Fluke Networks

 

6920 Seaway Boulevard, MS 143F

 

Everett WA 98203 USA

Fluke Networks operates in more than 50 countries worldwide. For more 
contact information, visit our website.

Specifications 

The DSX-CHA021 and DSX-CHA-M12-X adapters meet all measurement 
accuracy specifications for Level IIe test equipment. For more information, 
visit the Fluke Networks website.

Life of adapter contacts (typical):

 >5,000 cycles

Dimensions: 

3.0 in x 2.1 in x 1.2 in (75 mm x 54 mm x 30 mm) (each 

adapter)

Weight:

 2.6 oz (74 g) (each adapter)

Содержание DSX-CHA-M12-X-S

Страница 1: ...t 100BASE TX networks have 4 position D coded female connectors DSX CHA M12 X adapters for Gigabit Ethernet 10GBASE T have 8 position X coded female connectors DSX Firmware Requirements Your DSX Cable...

Страница 2: ...ct Category With reference to the equipment types in the WEEE Directive Annex I this product is classed as category 9 Monitoring and Control Instrumentation product Do not dispose of this product as u...

Страница 3: ...rs are at an ambient temperature between 50 F and 104 F 10 C and 40 C 2 Connect the main and remote testers together as shown at the top or bottom of Figure 1 3 On the home screen tap TOOLS then tap S...

Страница 4: ...ect type is not in the LAST USED list tap MORE tap Manufacturers tap the correct manufacturer then tap a cable type Shield Test Shows only for shielded cable types To get a FAIL result if the shield i...

Страница 5: ...5 U05 EPS Figure 2 Connections for Channel Tests with Two M12 Connectors Switch Channel 90 m maximum 295 ft M12 M12 M12 Variable frequency drive Main and remote testers with M12 adapters PLC...

Страница 6: ...and an M12 Connector Channel 90 m maximum 295 ft PLC Switch M12 M12 Variable frequency drive RJ45 cable from switch M12 Main tester with DSX CHA004 channel adapter Remote tester with M12 adapter Chan...

Страница 7: ...RJ45 Connectors Switch PLC Channel 90 m maximum 295 ft Variable frequency drive M12 M12 M12 RJ45 cable from switch RJ45 cable from VFD Main and remote testers with DSX CHA004 channel adapters Channel...

Страница 8: ...ed cable types To get a FAIL result if the shield is open select On See the Versiv Series Users Manual for more information Test Limit If the correct patch cord limit is not in the LAST USED list tap...

Страница 9: ...atest version of firmware is available at no charge on the Fluke Networks website Contact Fluke Networks www flukenetworks com support info flukenetworks com 1 800 283 5853 1 425 446 5500 Fluke Networ...

Страница 10: ...behalf To obtain service during the warranty period contact your nearest Fluke Networks authorized service center to obtain return authorization information then send your defective product to that S...

Отзывы: