Unpacking and Inspection 

Follow standard receiving practices upon receipt of the instrument. Check the shipping carton for 

damage. If damage is found, stop unpacking the instrument. Notify the carrier and ask for an 

agent to be present while the instrument is unpacked. There are no special unpacking instructions, 

but be careful not to damage the instrument when unpacking it. Inspect the instrument for physi-

cal damage such as bent or broken parts, dents, or scratches. 

Technical Support 

For application support or answers to technical questions, either email 

[email protected]

 or call 1-800- 648-7952 or 1-425-446-6945. 

Claims 

Our routine method of shipment is via common carrier, FOB origin. Upon delivery, if physical 

damage is found, retain all packing materials in their original condition and contact the carrier 

immediately to file a claim. If the instrument is delivered in good physical condition but does not 

operate within specifications, or if there are any other problems not caused by shipping damage, 

please contact Fluke Biomedical or your local sales representative. 

Standard Terms and Conditions 

Refunds and Credits 

Please note that only serialized products and their accessory items (i.e., products and 

items bearing a distinct serial number tag) are eligible for partial refund and/or credit. 

Nonserialized parts and accessory items (e.g., cables, carrying cases, auxiliary modules, 

etc.) are not eligible for return or refund. Only products returned within 90 days from the date 

of original purchase are eligible for refund/credit. In order to receive a partial refund/credit of a 

product purchase price on a serialized product, the product must not have been damaged by the 

customer or by the carrier chosen by the customer to return the goods, and the product must be 

returned complete (meaning with all manuals, cables, accessories, etc.) and in “as new” and re-

salable condition. Products not returned within 90 days of purchase, or products which are not in 

“as new” and resalable condition, are not eligible for credit return and will be returned to the cus-

tomer. The Return Procedure (see below) must be followed to assure prompt refund/credit. 

Restocking Charges 

Products returned within 30 days of original purchase are subject to a minimum restock-

ing fee of 15 %. Products returned in excess of 30 days after purchase, but prior to 90 

days, are subject to a minimum restocking fee of 20 %. Additional charges for damage 

and/or missing parts and accessories will be applied to all returns.  

Return Procedure 

All items being returned (including all warranty-claim shipments) must be sent freight-prepaid to 

our factory location. When you return an instrument to Fluke Biomedical, we recommend using 

United Parcel Service, Federal Express, or Air Parcel Post. We also recommend that you insure 

your shipment for its actual replacement cost. Fluke Biomedical will not be responsible for lost 

shipments or instruments that are received in damaged condition due to improper packaging or 

handling.  
Use the original carton and packaging material for shipment. If they are not available, we rec-

ommend the following guide for repackaging: 

ƒ

 

Use a double–walled carton of sufficient strength for the weight being shipped. 

ƒ

 

Use heavy paper or cardboard to protect all instrument surfaces. Use nonabrasive 

material around all projecting parts. 

ƒ

 

Use at least four inches of tightly packed, industry-approved, shock-absorbent 

material around the instrument. 

Returns for partial refund/credit:  

Содержание DPM2 Plus

Страница 1: ...DPM2 Plus Digital Pressure Meter Operators Manual PN 2572323 March 2006 2006 Fluke Corporation All rights reserved Printed in USA All product names are trademarks of their respective companies...

Страница 2: ...d you may also have other rights which vary from state to state province to province or country to coun try This warranty is limited to repairing the instrument to Fluke Biomedical s specifications Wa...

Страница 3: ...d product the product must not have been damaged by the customer or by the carrier chosen by the customer to return the goods and the product must be returned complete meaning with all manuals cables...

Страница 4: ...libration measurements are traceable to the National Institute of Standards and Technology NIST Devices for which there are no NIST calibration standards are measured against in house performance stan...

Страница 5: ...ons 2 Service Information 3 Part Numbers 3 Meter Features 4 Making Measurements 5 Zeroing 5 Connecting the Equipment under Test 6 Pressure Measurements 6 Measuring Gas and Gaseous Mixtures 6 Measuring...

Страница 6: ...Tables Table Title Page 1 Switch Positions 5 2 Compatible Agents 8 3 Pressure Conversion Chart 10 List of Figures Figure Title Page 1 Front panel controls and indicators 4 2 Setup for Measuring Liqui...

Страница 7: ...osphere c centi 10 2 cm centimeter cm H20 centimeters of water H20 water Hg mercury in inch lb pound LCD liquid crystal display m meter m milli 10 3 mm millimeter mmHg millimeters of mercury psi pound...

Страница 8: ......

Страница 9: ...easure and verify the positive or negative pressures from pneumatic as well as hydraulic sources Some of the Meter applications are Checking static cuff pressure and cuff pressure variations of pneuma...

Страница 10: ...ly securely clamped reinforced tubing General Specifications Power Requirements One 9 volt battery NEDA 6LR61 IEC 1604A Battery Life 60 hours of continuous use Operating Temperature 0 C to 30 C 32 F t...

Страница 11: ...rned to the factory yearly for calibration For return instructions see the section titled Returns for service repair calibration Part Numbers Standard Fluke Part Operators Manual 2572323 Catheter Adap...

Страница 12: ...Use a screwdriver to adjust if display is not reading zero when vented to atmosphere Liquid Crystal LCD Ranges 13 50 to 100 0 psi 13 50 to 15 50 psi 374 to 429 in H20 949 to 1090 cm H20 698 to 802 mm...

Страница 13: ...seconds for the display to settle to zero when the Meter is initially turned on and vented to atmosphere The Meter has five different range measurement units as indicated on the front panel overlay i...

Страница 14: ...If the display shows a 1 in the far left position with all other digits blank this means the limits of the selected range have been exceeded Measuring Gas and Gaseous Mixtures No special procedures ar...

Страница 15: ...100psi mmHg VOLTAGE OUTPUT 0 01 V psi 100 psi RANGE 0 1 V psi ON OTHER RANGE OFF cmH2 0 Air Up Liquid ehg2 eps Figure 2 Setup for Measuring Liquid Medium Voltage Output Jack The voltage output jack is...

Страница 16: ...2 Compatible Agents Agent Temperature Concentration Acetic Acid Room temperature 5 Acetone Room temperature 100 Ammonia Room temperature 30 35 Benzaldehyde Room temperature 100 Benzyl Alcohol Room tem...

Страница 17: ...ochloric Acid Room temperature 10 Hydrogen Peroxide Room temperature 10 30 Methanol Vapor Room temperature 100 Methyl Alcohol Room temperature 100 Oleic Acid Room temperature 100 Potassium Permanganat...

Страница 18: ...14 696 1 9337 10 2 in Hg 0 C 2 0359 1 7 3419 10 2 3 9368 10 2 2 8959 10 3 29 920 3 9368 10 2 in H20 20 C 27 73 13 620 1 0 53622 3 9440 10 2 407 52 0 53622 mmHg 0 C 51 714 25 401 1 8649 1 7 3558 10 2...

Отзывы: