background image

 

LIMITED WARRANTY AND LIMITATION OF LIABILITY 

Each Fluke product is warranted to be free from defects in material and workmanship under normal use and 
service. The warranty period is three years and begins on the date of shipment. Parts, product repairs, and 
services are warranted for 90 days. This warranty extends only to the original buyer or end-user customer of 
a Fluke authorized reseller, and does not apply to fuses, disposable batteries, or to any product which, in 
Fluke's opinion, has been misused, altered, neglected, contaminated, or damaged by accident or abnormal 
conditions of operation or handling. Fluke warrants that software will operate substantially in accordance 
with its functional specifications for 90 days and that it has been properly recorded on non-defective media. 
Fluke does not warrant that software will be error free or operate without interruption. 

Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers 
only but have no authority to extend a greater or different warranty on behalf of Fluke. Warranty support is 
available only if product is purchased through a Fluke authorized sales outlet or Buyer has paid the 
applicable international price. Fluke reserves the right to invoice Buyer for importation costs of 
repair/replacement parts when product purchased in one country is submitted for repair in another country. 

Fluke's warranty obligation is limited, at Fluke's option, to refund of the purchase price, free of charge repair, 
or replacement of a defective product which is returned to a Fluke authorized service center within the 
warranty period. 

To obtain warranty service, contact your nearest Fluke authorized service center to obtain return 
authorization information, then send the product to that service center, with a description of the difficulty, 
postage and insurance prepaid (FOB Destination). Fluke assumes no risk for damage in transit. Following 
warranty repair, the product will be returned to Buyer, transportation prepaid (FOB Destination). If Fluke 
determines that failure was caused by neglect, misuse, contamination, alteration, accident, or abnormal 
condition of operation or handling, including overvoltage failures caused by use outside the product’s 
specified rating, or normal wear and tear of mechanical components, Fluke will provide an estimate of repair 
costs and obtain authorization before commencing the work. Following repair, the product will be returned to 
the Buyer transportation prepaid and the Buyer will be billed for the repair and return transportation charges 
(FOB Shipping Point). 

THIS WARRANTY IS BUYER'S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER 
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY 
OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. FLUKE SHALL NOT BE LIABLE 
FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, 
INCLUDING LOSS OF DATA, ARISING FROM ANY CAUSE OR THEORY. 

Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or 
limitation of incidental or consequential damages, the limitations and exclusions of this warranty may not 
apply to every buyer. If any provision of this Warranty is held invalid or unenforceable by a court or other 
decision-maker of competent jurisdiction, such holding will not affect the validity or enforceability of any other 
provision. 

Fluke Corporation
P.O. Box 9090 
Everett, WA  98206-9090 
U.S.A. 

Fluke Europe B.V.
P.O. Box 1186 
5602 BD Eindhoven 
The Netherlands 

 

 

 

11/99

Содержание CNX i3000

Страница 1: ...pecifications are subject to change without notice All product names are trademarks of their respective companies CNX i3000 Wireless iFlex Calibration Manual rie enia na presn meranie Elso Philips Ser...

Страница 2: ...r nearest Fluke authorized service center to obtain return authorization information then send the product to that service center with a description of the difficulty postage and insurance prepaid FOB...

Страница 3: ...pment 5 Performance Tests 5 Test the Display 5 Backlight 6 Keypad Test 6 AC Current Test 6 Before Calibration Adjustment 9 Maintenance Mode 9 Password Entry 9 Change the Password 9 Restore the Default...

Страница 4: ...CNX i3000 Calibration Manual ii...

Страница 5: ...iii List of Tables Table Title Page 1 Symbols 3 2 Required Equipment 5 3 Performance Tests 6 4 Calibration Adjustment 11 5 User Replaceable Parts 13...

Страница 6: ...CNX i3000 Calibration Manual iv...

Страница 7: ...s Figure Title Page 1 All Segments of the Display 5 2 Performance Test Connections for Applied Voltages 7 3 Performance Test Connections for Applied Current 8 4 Calibration Password Reset 10 5 Battery...

Страница 8: ...CNX i3000 Calibration Manual vi...

Страница 9: ...lowing telephone numbers Technical Support USA 1 800 44 FLUKE 1 800 443 5853 Calibration Repair USA 1 888 99 FLUKE 1 888 993 5853 Canada 1 800 36 FLUKE 1 800 363 5853 Europe 31 402 675 200 Japan 81 3...

Страница 10: ...you operate the Product Replace the batteries when the low battery indicator shows to prevent incorrect measurements Have an approved technician repair the Product Use only specified replacement parts...

Страница 11: ...he low voltage MAINS installation CAT III Measurement Category III is applicable to test and measuring circuits connected to the distribution part of the building s low voltage MAINS installation CAT...

Страница 12: ...000 m 6561 68 ft Storage Altitude 12 000 m 39370 079 ft Temperature Coefficient Add 0 1 X specified accuracy C 18 C or 28 C Add 0 1 X specified accuracy F 64 4 F or 82 4 F Safety Rating IEC 61010 1 60...

Страница 13: ...trical shock fire or personal injury do not perform the performance test procedures unless the Product is fully assembled The performance tests verify the full operation of the Product and measure the...

Страница 14: ...battery is good and replace it if necessary See Battery Replacement 3 Warm up the Calibrator as necessary Refer to its specifications 4 Let the temperature of the unit under test UUT become stable to...

Страница 15: ...2 10 8 0 3 A 500 Hz 0 1 14 05 15 95 1 180 mV 500 Hz 0 1 581 5 618 5 1 300 mV 500 Hz 1 965 1035 1 750 mV 500 Hz 1 2420 2580 Freq R coil 5 Hz 0 3 A 0 1 0 5 4 5 5 5 50 Hz 0 4 A 0 1 49 3 50 8 500 Hz 0 325...

Страница 16: ...V RMS MAX 20V PK MAX 1V PK MAX 20V PK MAX NORMAL AUX TRIG OUT SCOPE V RTD A SENSE AUX V 150V PK MAX 20V PK MAX 50 Turn Current Coil CNX i3000 Conductor hca009 eps Figure 3 Performance Test Connections...

Страница 17: ...g the procedures packaging and bench techniques that are recommended The following practices should be followed to minimize damage to S S static sensitive devices 1 MINIMIZE HANDLING 2 KEEP PARTS IN O...

Страница 18: ...H OPEN EDGE CONNECTOR EXCEPT AT STATIC FREE WORK STATION PLACING SHORTING STRIPS ON EDGE CONNECTOR HELPS PROTECT INSTALLED S S DEVICES 9 HANDLE S S DEVICES ONLY AT A STATIC FREE WORK STATION 10 ONLY A...

Страница 19: ...choice The subsequent flashes 5 Do steps 3 and 4 again to enter the subsequent digits of the four number password 6 When all of the correct digits are entered push to confirm the input If the correct...

Страница 20: ...the bottom case screws Two of the screws are inside of the battery door 3 Keep the pca in the top case 4 Apply 3 0 V across the battery contacts on the pca Note the polarity that is shown in Figure 4...

Страница 21: ...calibration step number advances before you change the calibrator source Some adjustment steps can take several seconds to execute before the Product goes to the subsequent step Set the Calibrator to...

Страница 22: ...er test Remove batteries to prevent battery leakage and damage to the Product if it is not used for an extended period Be sure that the battery polarity is correct to prevent battery leakage To change...

Страница 23: ...e shown in Table 5 Table 5 User Replaceable Parts Fluke Part Number Description Qty 4130305 FLK 3000 2003 DOOR BATTERY 1 3676410 FLUKE I2500 10 IFLEX 2500A PROBE 10IN 1 1881997 TPAK meter hanging kit...

Страница 24: ...CNX i3000 Calibration Manual 14 rie enia na presn meranie http www elso sk...

Отзывы: