Testing for Continuity
The continuity function lets you test for opens and shorts
on the 8-pin modular jack or the coaxial connector. The
tester shows a bar graph of resistance from 500
Ω
to
5000
Ω
, and the tester’s audible tones vary depending on
the resistance measured.
On an 8-pin jack, the tester checks for continuity
between the wires in the pair you select. Pair 12 is the
default.
To check continuity:
1
Verify that the circuit to be tested is not powered or
in service. For cabling, use
DISCOVER
mode to check
for active services. For other types of circuits or
components, use a voltage meter to check for
power.
2
Turn the rotary switch to
DIAG
.
3
Use
D
to highlight
Continuity
; then press
H
,
J
, or
P
.
4
To check continuity using the coaxial connector,
press
K
c
.
5
Connect the tester to the circuit, component, or
cabling to be tested. Figure 23 shows connections
using the optional 8-clip test lead.
Содержание CableIQ
Страница 6: ...CableIQ Qualification Tester Users Manual iv ...
Страница 10: ...CableIQ Qualification Tester Users Manual viii ...
Страница 18: ...CableIQ Qualification Tester Users Manual 8 Physical Features avv01f eps Figure 2 Features ...
Страница 43: ...Qualifying Cabling with the Autotest 33 avv34f eps Figure 13 Autotest Connections for Coaxial Cabling ...
Страница 57: ...Discovering Cabling Characteristics 47 avv07f eps Figure 19 Using Multiple Remote ID Locators ...
Страница 59: ...Using the Toner 49 avv06f eps Figure 20 Using the Toner twisted pair example with IntelliTone probe ...
Страница 65: ...Using the Continuity Toner 55 avv38f eps Figure 24 Using the Continuity Toner to Test Security Switches ...
Страница 82: ...CableIQ Qualification Tester Users Manual 72 ...
Страница 88: ...CableIQ Qualification Tester Users Manual 78 ...
Страница 92: ...CableIQ Qualification Tester Users Manual 82 ...