Digital Multimeter
Performance Tests
25
Basic Operability Tests
Refer to the following sections to test the basic operability of the Meter.
Testing the Fuses
Refer to “Testing Fuses (F1 and F2)”.
Testing the Display
Turn the Meter on while holding down
D
to view all segments of the display.
Compare the display with the appropriate examples in Figure 5 and Table 14.
3
2
10
11
14
6
1
12
Hi Res
16
4
5
7
8
9
13
17
15
18
aom1_af.eps
Figure 5. Display Features
Table 14. Display Features
Number Feature
Indication
Y
Polarity indicator for the analog bar graph.
A
Trig
Y
Positive or negative slope indicator for Hz/duty cycle triggering.
B
X
The continuity beeper is on.
C
W
Relative (REL) mode is active.
D
g
Smoothing is active.
E
-
Indicates negative readings. In relative mode, this sign indicates that the
present input is less than the stored reference.
F
Z
Indicates the presence of a high voltage input. Appears if the input voltage is
30 V or greater (ac or dc). Also appears in low pass filter mode. Also appears
in cal, Hz, and duty cycle modes.
G
RS
AutoHOLD is active.
H
S
Display Hold is active.
I
p
Indicates the Meter is in Peak Min Max mode and the response time is 250
µ
s
J
m
MAX
MIN AVG
Indicators for minimum-maximum recording mode.
K
K
Low pass filter mode.
Содержание 87 V/AN
Страница 6: ...87 V AN Service Manual iv...
Страница 8: ...87 V AN Service Manual vi...
Страница 47: ...39 Digital Multimeter Schematic Diagrams Figure 8 A1 LED PCA 8X 5 4001...