AC Voltage specifications
AC Voltage
[1] [2] [6] [7]
Full Scale
Uncertainty Relative to Cal Stds
24 hour
TCal ±1 °C
365 day
TCal ±1 °C
Absolute Uncertainties
[9]
200 mV
199.999 9
1 - 10
80 + 70
120 + 70
120 + 70
160 + 70
165 + 70
10 - 40
80 + 20
120 + 20
120 + 20
130 + 20
140 + 20
40 - 100
60 + 20
100 + 20
100 + 20
110 + 20
115 + 20
100 - 2k
40 + 10
100 + 10
100 + 10
105 + 10
110 + 10
2k - 10k
60 + 20
100 + 20
100 + 20
105 + 20
135 + 20
10k - 30k
250 + 30
300 + 40
300 + 40
305 + 40
340 + 40
30k - 100k
400 + 100
700 + 100
700 + 100
705 + 100
765 + 100
2 V,
1.999 999
1 - 10
70 + 60
100 + 60
100 + 60
140 + 60
150 + 60
20 V &
19.999 99
10 - 40
70 + 10
100 + 10
100 + 10
105 + 10
115 + 10
200 V
199.999 9
40 - 100
50 + 10
80 + 10
80 + 10
85 + 10
90 + 10
100 - 2k
30 + 10
60 + 10
60 + 10
65 + 10
75 + 10
2k - 10k
50 + 10
80 + 10
80 + 10
85 + 10
110 + 10
10k - 30k
100 + 20
200 + 20
200 + 20
205 + 20
220 + 20
30k - 100k
250 + 100
500 +100
500 +100
505 + 100
570 + 100
100k - 300k 0.15% + 0.1% 0.3% + 0.1% 0.3% + 0.1%
0.3% + 0.1%
0.3% + 0.1%
300k - 1M
1% + 0.5%
1% + 1%
1% + 1%
1% + 1%
1% + 1%
1000 V
[8]
1050.000
1 - 10
70 + 70
100 + 70
100 + 70
140 + 70
150 + 70
10 - 40
70 + 20
100 + 20
100 + 20
110 + 20
120 + 20
40 - 10k
50 + 20
80 + 20
80 + 20
95 + 20
115 + 20
10k - 30k
100 + 40
200 + 40
200 + 40
205 + 40
225 + 40
30k - 100k
250 + 200
500 + 200
500 + 200
510 + 200
580 + 200
200 mV
199.999 9
1 - 10
90 + 80
140 + 80
140 + 80
200 + 80
210 + 80
10 - 40
90 + 25
140 + 25
140 + 25
145 + 25
160 + 25
40 - 100
70 + 25
115 + 25
115 + 25
125 + 25
135 + 25
100 - 2k
45 + 12
115 + 12
115 + 12
125 + 12
135 + 12
2k - 10k
70 + 25
115 + 25
115 + 25
125 + 25
165 + 25
10k - 30k
270 + 35
340 + 50
340 + 50
345 + 50
395 + 50
30k - 100k
450 + 120
750 + 120
750 + 120
755 + 120
855 + 120
2 V,
1.999 999
1 - 10
80 + 70
115 + 70
115 + 70
180 + 70
190 + 70
20 V &
19.999 99
10 - 40
80 + 12
115 + 12
115 + 12
120 + 12
135 + 12
200 V
199.999 9
40 - 100
60 + 12
90 + 12
90 + 12
95 + 12
110 + 12
100 - 2k
35 + 12
70 + 12
70 + 12
75 + 12
90 + 12
2k - 10k
60 + 12
90 + 12
90 + 12
95 + 12
135 + 12
10k - 30k
115 + 25
240 + 25
240 + 25
245 + 25
260 + 25
30k - 100k
270 + 120
550 + 120
550 +120
555 + 120
650 + 120
100k - 300k 0.15% + 0.12% 0.3% + 0.12% 0.3% + 0.12%
0.3% + 0.12%
0.3% + 0.12%
300k - 1M
1% + 0.6%
1% + 1.2%
1% + 1.2%
1% + 1.2%
1% + 1.2%
1000 V
[8]
1050.000
1 - 10
80 + 80
115 + 80
115 + 80
180 + 80
190 + 80
10 - 40
80 + 25
115 + 25
115 + 25
135 + 25
145 + 25
40 - 10k
60 + 25
90 + 25
90 + 25
110 + 25
140 + 25
10k - 30k
115 + 50
240 + 50
240 + 50
250 + 50
265 + 50
30k - 100k
270 + 250
600 + 250
600 + 250
615 + 250
700 + 250
90 day
TCal ±1 °C
Range
95 % Confidence Level
99 % Confidence Level
Frequency (Hz)
365 day
TCal ±1 °C
365 day
TCal ±5 °C
±
(ppm R ppm Range)
[4]