Vibration Tester
Viewer Software
19
Clear Memory
Select the
Clear Memory
option on the Instrument Setup
screen to erase all measurement and diagnosis data. A
sequence of confirmation messages display:
gbk31.bmp
If you select
Yes,
another confirmation message displays:
gbk32.bmp
Select
Yes
to clear the memory. This action erases all
stored measurement and diagnosis data.
Viewer Software
The 810 Vibration Tester includes Viewer software that
lets you do tasks from a computer. With the basic
features of the software you can:
•
download a Machine Setup from the Tester
•
set up a new machine
•
make a copy of a Machine Setup
•
change a Machine Setup
•
look at cited peaks graphs, vibration spectra, and
time waveforms
•
zoom-in and zoom-out of data views
•
make a backup of the diagnosis data from a
measured machine
•
import and look at the thermographic image of a
machine
Additionally, you can configure the Machine Setups with
the software and upload them to the Tester. This Machine
Setup procedure is much the same as the Machine Setup
wizard in the Tester. For external analysis of the fault
data, you can export the Machine Setup, diagnosis data,
and fault data to a PDF to send to a vibration test
consultant.