Technical Data
Transmitter:
Outputsignal....................................125 kHz
External voltage detection
Voltage Range ................................12...400 V
Frequency Range............................0...60 Hz
Display ............................................LCD with display of functions
External Voltge Detection ..............max. 400 V AC/DC
Over Voltage Category ....................CAT III/300 V
Pollution Degree..............................2
Power Supply ..................................6 x 1,5 V, IEC LR6
Power Consumption ........................max. 40 mA
Fuse ................................................F 0.5 A 500V, 6.3 x 32 mm
Temperature
Range (Work)..................................0...40°C, max 80% rel. humidity (not condens.)
Temperature Range (Storage) ........-20...+60°C, max 80% rel. humidity (not condens.)
Height above MSL ..........................up to 2000 meters
Dimensions ....................................190 x 85 x 50 mm
Weight ............................................approx. 260 g (without battery)
........................................................approx. 400 g (with battery)
Receiver:
Tracing depth ..................................The tracing depth depends of medium and application
Cable Locator Mode........................approx. 0...2 meters (single-pole application)
........................................................approx. 0...0.5 meters (double-pole application)
Voltage detection ............................approx. 0...0.4 meters
Display ............................................LCD with functions- and bargraph
Power Supply ..................................1 x 9 V, IEC 6LR61
Power Consumption ........................approx. 17 mA (without backlight or lamp)
........................................................approx. 50 mA (with backlight)
........................................................max. 70 mA (Backlight and lamp)
Temperature Range (Work) ............0...40°C, max 80% rel. humidity (not condens.)
Temperature Range (Storage) ...... -20...+60°C, max 80% rel. humidity (not condens.)
Height above MSL ..........................up to 2000 meters.
Dimensions ....................................250 x 65 x 45 mm
Weight ............................................approx. 220 g (without battery)
........................................................approx. 270 g (with battery)
28
Fluke 2042
Technical Data