The tracing depth amounts to 0...0,5 meters..The
tracing depth depends of medium and application
When connecting in live circuits, safety regulations
must be followed.
The switching with button 4 from »LEVEL I« to
»LEVEL III« the sensitvity of Distance is increased
up to factor 5.
Locating and tracing of lines, sockets, switches and junctions in
house installations circuits (one-pole application)
Requirements:
• The circuit must be dead.
• Neutral line and ground must be connected
and fully operational.
• Connect transmitter to phase and neutral ac-
cording to figure 7.
• Carry out this example as described in the ap-
plication example.
With the one-pole indication, also lateral circuit
branches can be traced.
If the supply cable fed with the signal via the transmitter is located, e.g. directly in parallel to
other conductors (e.g. cable duct), or if these conductors are crossed, the signal is also input
into the other conductors. The fuse must be removed during this example.
The switching with button 4 from »LEVEL I« to »LEVEL III« the sensitvity of Distance is increa-
sed up to a factor of 5.
Setup: manual mode, minimal sensitivity. Tracing depth max. 2 meters.