110 PLUS and 115
Users Manual
10
When you turn the Meter on, it defaults to Autorange and
Auto
is displayed.
1.
To enter the Manual Range mode, press
.
Manual
is
displayed.
2.
In the Manual Range mode, press
to increment the
range. After the highest range, the Meter wraps to the lowest
range.
Note
You cannot manually change the range in the MIN
MAX AVG or Display HOLD modes.
If you press
while in
MIN MAX AVG or
Display Hold
, the Meter beeps twice, indicating
an invalid operation and the range does not
change.
3.
To exit Manual Range, press
for at least 1 second or
turn the rotary switch. The Meter returns to Autorange and
Auto
is displayed.
Power-Up Options
To select a Power-Up Option, hold down the button indicated in
the following table while turning the Meter on. Power-Up Options
are canceled when you turn the Meter off and when sleep mode
is activated.
Button Power-Up
Options
Turns on all display segments.
Disables beeper.
is displayed when
enabled.
Enables low impedance capacitance
measurements.
is displayed when
enabled. See page 14.
Disables automatic power-down ("Sleep
mode").
is displayed when enabled.
Disables auto backlight off.
is displayed
when enabled.