Warranty and Product Support 

Fluke Biomedical warrants this instrument against defects in materials and workmanship for one year from 

the date of original purchase OR two years if at the end of your first year you send the instrument to a Fluke 

Biomedical service center for calibration.  You will be charged our customary fee for such calibration. During 

the warranty period, we will repair or at our option replace, at no charge, a product that proves to be 

defective, provided you return the product, shipping prepaid, to Fluke Biomedical. This warranty covers the 

original purchaser only and is not transferable.  The warranty does not apply if the product has been 

damaged by accident or misuse or has been serviced or modified by anyone other than an authorized Fluke 

Biomedical service facility. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR 

PURPOSE, ARE EXPRESSED OR IMPLIED.  FLUKE SHALL NOT BE LIABLE FOR ANY SPECIAL, 

INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, 

ARISING FROM ANY CAUSE OR THEORY.  

This warranty covers only serialized products and their accessory items that bear a distinct serial number 

tag. Recalibration of instruments is not covered under the warranty. 

This warranty gives you specific legal rights and you may also have other rights that vary in different 

jurisdictions. Since some jurisdictions do not allow the exclusion or limitation of an implied warranty or of 

incidental or consequential damages, this limitation of liability may not apply to you.  If any provision of this 

warranty is held invalid or unenforceable by a court or other decision-maker of competent jurisdiction, such 

holding will not affect the validity or enforceability of any other provision. 

7/07 

 

Содержание 05-443

Страница 1: ...2014 2014 Fluke Corporation All rights reserved Specifications are subject to change without notice All product names are trademarks of their respective companies 05 443 05 444 Digital Wall Mount Are...

Страница 2: ...ke Biomedical service facility NO OTHER WARRANTIES SUCH AS FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSED OR IMPLIED FLUKE SHALL NOT BE LIABLE FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMA...

Страница 3: ...cations or if there are any other problems not caused by shipping damage please contact Fluke Biomedical or your local sales representative Returns and Repairs Return Procedure All items being returne...

Страница 4: ...ance standards using accepted test procedures WARNING Unauthorized user modifications or application beyond the published specifications may result in electrical shock hazards or improper operation Fl...

Страница 5: ...32 Output 12 9 Pin Data Connector Female Sockets 13 Internal Detector Setups 13 Model 05 443 and Model 05 443 2200 13 Model 05 444 14 Common Options and Modifications 15 Time and Date Stamp Option 15...

Страница 6: ...05 443 05 444 Users Manual ii...

Страница 7: ...iii List of Figures Figure Title Page 1 Front Panel 2 2 Left Side Panel 6 3 Alarm Point Notice 7...

Страница 8: ...05 443 05 444 Users Manual iv...

Страница 9: ...peration Parameters are protected under a calibration cover Calibration is easily accomplished by moving the CAL dipswitch to the right and using the pushbuttons to increment or decrement the calibrat...

Страница 10: ...event possible electrical shock fire or personal injury Read all safety information before you use the Product Carefully read all instructions Do not use the Product around explosive gas vapor or in d...

Страница 11: ...parts Do not use the Product if it is damaged Disable the Product if it is damaged Use only specified replacement fuses For continued protection against the risk of fire replace only with fuse of the...

Страница 12: ...ay in R hr mR hr R hr Sv h mSv h Sv h rem hr mrem hr rem hr cpm cps and others Linearity Readings within 10 of true value with detector connected Operating Range 05 443 and 05 443 2200 1 Sv h to 10 mS...

Страница 13: ...ned on Construction Aluminum housing with ivory powder coat finish Temperature range Normal use 20 C to 50 C 4 F to 122 F May be certified for operation from 40 C 40 F Maximum relative humidity Less t...

Страница 14: ...oduct is designed for ease of use This section of the manual is designed to help the first time user get started Initial power up and basic features of the instrument will be discussed in this section...

Страница 15: ...e 3 Alarm Point Notice Initial power up by way of the power switch on the left side panel will momentarily activate the internal front panel lights sound the audio and display 8888 on the 4 digit LED...

Страница 16: ...r dead time correction by pressing down on the DEAD TIME button The dead time correction will be displayed as long as the button is pressed The dead time correction is in units of microseconds The dea...

Страница 17: ...ash your hands after handling Radiation exposure while handling this source is very minimal with no identified long or short term risks Although the amount of radiation given off by exempt sources is...

Страница 18: ...nown point at some given reading HV Used to set the high voltage required for detector operation Adjustable from 0 V dc to 2500 V dc The high voltage required will depend on the type of detector used...

Страница 19: ...CAL MODE switch back to the left locks the parameters and disables any further changes Dipswitch 2 The second switch LATCH ALARM changes the high alarm to a latching alarm This switch does not affect...

Страница 20: ...top bit no handshaking buffer size of 8k OPEN COM1 2400 n 8 1 bin CS0 DS0 CD0 RB0 FOR INPUT AS 1 open up filename for output CLS clear the screen LOCATE 1 PRINT Press Esc key to stop reading data COM...

Страница 21: ...ital signal outputs are open drain 2N7002 outputs able to sink about 50 mA each Internal Detector Setups Model 05 443 and Model 05 443 2200 Typical response and set points for the Product with interna...

Страница 22: ...ector is as follows Operating Voltage 550 V dc Threshold 100 mV dc Calibration Constant 150 cpm mR hr Dead Time Correction 30 sec to 150 sec Linear Range with DTC 1 mR hr to 8 R hr Typical Checkpoints...

Страница 23: ...hose buttons are pressed The year can be adjusted from 0000 to 9999 Check the hours and minutes HHMM by pressing the LOW ALARM and DEAD TIME buttons simultaneously The hours and minutes will be displa...

Страница 24: ...d to a low radiation field A low radiation field in this case is defined as a field where dead time losses do not exceed 5 The calibration constant is usually given for a certain detector Once the cal...

Страница 25: ...If exposure to chemicals occurs clean with water and get medical aid Have an approved technician repair the Product Use only specified replacement parts Do not touch the center pin of the detector co...

Страница 26: ...ange of recyclable materials present in its products so that the user will have flexibility in following all local and federal laws The following types of recyclable materials are present in manufactu...

Страница 27: ...screws 1 648 in 1 648 in 3 in 3 in 2 679 in 0 in 0 in Anchors must be able to hold 12 pounds per screw and must be appropriate for wall construction Minimum clearance Drawing to actual size may be us...

Страница 28: ...05 443 05 444 Users Manual 20...