Digital Wall Mount-Area Monitor 

 

Safety Information 

 

Replace the mains power cord if the insulation is damaged 

or if the insulation shows signs of wear. 

 

Make sure the ground conductor in the mains power cord is 

connected to a protective earth ground. Disruption of the 

protective earth could put voltage on the chassis that could 

cause death.  

 

Do not put the Product where access to the mains power 

cord is blocked. 

 

Do not operate the Product with covers removed or the 

case open. Hazardous voltage exposure is possible. 

 

Batteries contain hazardous chemicals that can cause 

burns or explode. If exposure to chemicals occurs, clean 

with water and get medical aid. 

 

Have an approved technician repair the Product. 

 

Use only specified replacement parts. 

 

Do not use the Product if it is damaged. 

 

Disable the Product if it is damaged. 

 

Use only specified replacement fuses. 

 

For continued protection against the risk of fire, replace 

only with fuse of the specified type and current rating.  

 

The operator or responsible body is cautioned that the 

protection provided by the equipment may be impaired if 

the equipment is used in a manner not specified by Fluke 

Biomedical  

 

Only certified technician or calibration personnel should 

replace battery. 

 

Do not touch the circuit board in the calibration window due 

to potential for electric shock. 

 

Do not touch the center pin of the detector connector 

unless the unit has been turned off and power has been 

removed or at least 1 minute. 

 

To prevent contact with internal hazardous live parts that 

are accessible using a tool: turn off the Product and 

disconnect the power cord. Allow the Product to sit for 

1 minute before accessing internal components. 

Содержание 05-443

Страница 1: ...2014 2014 Fluke Corporation All rights reserved Specifications are subject to change without notice All product names are trademarks of their respective companies 05 443 05 444 Digital Wall Mount Are...

Страница 2: ...ke Biomedical service facility NO OTHER WARRANTIES SUCH AS FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSED OR IMPLIED FLUKE SHALL NOT BE LIABLE FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMA...

Страница 3: ...cations or if there are any other problems not caused by shipping damage please contact Fluke Biomedical or your local sales representative Returns and Repairs Return Procedure All items being returne...

Страница 4: ...ance standards using accepted test procedures WARNING Unauthorized user modifications or application beyond the published specifications may result in electrical shock hazards or improper operation Fl...

Страница 5: ...32 Output 12 9 Pin Data Connector Female Sockets 13 Internal Detector Setups 13 Model 05 443 and Model 05 443 2200 13 Model 05 444 14 Common Options and Modifications 15 Time and Date Stamp Option 15...

Страница 6: ...05 443 05 444 Users Manual ii...

Страница 7: ...iii List of Figures Figure Title Page 1 Front Panel 2 2 Left Side Panel 6 3 Alarm Point Notice 7...

Страница 8: ...05 443 05 444 Users Manual iv...

Страница 9: ...peration Parameters are protected under a calibration cover Calibration is easily accomplished by moving the CAL dipswitch to the right and using the pushbuttons to increment or decrement the calibrat...

Страница 10: ...event possible electrical shock fire or personal injury Read all safety information before you use the Product Carefully read all instructions Do not use the Product around explosive gas vapor or in d...

Страница 11: ...parts Do not use the Product if it is damaged Disable the Product if it is damaged Use only specified replacement fuses For continued protection against the risk of fire replace only with fuse of the...

Страница 12: ...ay in R hr mR hr R hr Sv h mSv h Sv h rem hr mrem hr rem hr cpm cps and others Linearity Readings within 10 of true value with detector connected Operating Range 05 443 and 05 443 2200 1 Sv h to 10 mS...

Страница 13: ...ned on Construction Aluminum housing with ivory powder coat finish Temperature range Normal use 20 C to 50 C 4 F to 122 F May be certified for operation from 40 C 40 F Maximum relative humidity Less t...

Страница 14: ...oduct is designed for ease of use This section of the manual is designed to help the first time user get started Initial power up and basic features of the instrument will be discussed in this section...

Страница 15: ...e 3 Alarm Point Notice Initial power up by way of the power switch on the left side panel will momentarily activate the internal front panel lights sound the audio and display 8888 on the 4 digit LED...

Страница 16: ...r dead time correction by pressing down on the DEAD TIME button The dead time correction will be displayed as long as the button is pressed The dead time correction is in units of microseconds The dea...

Страница 17: ...ash your hands after handling Radiation exposure while handling this source is very minimal with no identified long or short term risks Although the amount of radiation given off by exempt sources is...

Страница 18: ...nown point at some given reading HV Used to set the high voltage required for detector operation Adjustable from 0 V dc to 2500 V dc The high voltage required will depend on the type of detector used...

Страница 19: ...CAL MODE switch back to the left locks the parameters and disables any further changes Dipswitch 2 The second switch LATCH ALARM changes the high alarm to a latching alarm This switch does not affect...

Страница 20: ...top bit no handshaking buffer size of 8k OPEN COM1 2400 n 8 1 bin CS0 DS0 CD0 RB0 FOR INPUT AS 1 open up filename for output CLS clear the screen LOCATE 1 PRINT Press Esc key to stop reading data COM...

Страница 21: ...ital signal outputs are open drain 2N7002 outputs able to sink about 50 mA each Internal Detector Setups Model 05 443 and Model 05 443 2200 Typical response and set points for the Product with interna...

Страница 22: ...ector is as follows Operating Voltage 550 V dc Threshold 100 mV dc Calibration Constant 150 cpm mR hr Dead Time Correction 30 sec to 150 sec Linear Range with DTC 1 mR hr to 8 R hr Typical Checkpoints...

Страница 23: ...hose buttons are pressed The year can be adjusted from 0000 to 9999 Check the hours and minutes HHMM by pressing the LOW ALARM and DEAD TIME buttons simultaneously The hours and minutes will be displa...

Страница 24: ...d to a low radiation field A low radiation field in this case is defined as a field where dead time losses do not exceed 5 The calibration constant is usually given for a certain detector Once the cal...

Страница 25: ...If exposure to chemicals occurs clean with water and get medical aid Have an approved technician repair the Product Use only specified replacement parts Do not touch the center pin of the detector co...

Страница 26: ...ange of recyclable materials present in its products so that the user will have flexibility in following all local and federal laws The following types of recyclable materials are present in manufactu...

Страница 27: ...screws 1 648 in 1 648 in 3 in 3 in 2 679 in 0 in 0 in Anchors must be able to hold 12 pounds per screw and must be appropriate for wall construction Minimum clearance Drawing to actual size may be us...

Страница 28: ...05 443 05 444 Users Manual 20...

Отзывы: