Multi-Product Calibrator
Instruction Manuals
11
Instruction Manuals
The 5522A manual set provides complete information for operators. The set includes:
•
5522A Getting Started Manual
(PN 3795091)
•
5522A Operators Manual
provided on CD-ROM (PN 3795084)
5522A Getting Started Manual
This 5522A Getting Started Manual contains a brief introduction to the 5522A Manual
Set, instructions on how to get your calibrator prepared for operation and a complete set
of specifications.
5522A Operators Manual
The 5522A Operators Manual provides complete information for installing the 5522A
Calibrator and operating it from the front panel keys and in remote configurations. This
manual also provides a glossary of calibration, specifications, and error code information.
The Operators Manual includes the following topics:
•
Installation
•
Operating controls and features, including front-panel operation.
•
Remote operation (IEEE-488 bus or serial port remote control)
•
Serial port operation (printing, displaying, or transferring data, and setting up for
serial port remote control)
•
Operator maintenance, including verification procedures and calibration approach for
the 5522A.
•
Oscilloscope calibration options
•
Accessories
General Specifications
The following tables list the 5522A specifications. All specifications are valid after allowing a warm-up period of
30 minutes, or twice the time the 5522A has been turned off. (For example, if the 5522A has been turned off for
5 minutes, the warm-up period is 10 minutes.)
All specifications apply for the temperature and time period indicated. For temperatures outside of tcal
±
5
°
C (tcal is the
ambient temperature when the 5522A was calibrated), the temperature coefficient as stated in the General Specifications
must be applied.
The specifications also assume the Calibrator is zeroed every seven days or whenever the ambient temperature changes
more than 5
°
C. The tightest ohms specifications are maintained with a zero cal every 12 hours within
±
1
°
C of use.
Also see additional specifications later in this chapter for information on extended specifications for ac voltage and
current.
Warmup Time
........................................................ Twice the time since last warmed up, to a maximum of 30 minutes.
Settling Time
......................................................... Less than 5 seconds for all functions and ranges except as noted.
Standard Interfaces
.............................................. IEEE-488 (GPIB), RS-232
Temperature
Operating ............................................................ 0
°
C to 50
°
C
Calibration (tcal).................................................. 15
°
C to 35
°
C
Storage ............................................................... -20
°
to +50
°
C; The DC current ranges 0 to 1.09999 A and 1.1 A to
2.99999 A are sensitive to storage temperatures above 50
°
C. If the
5522A is stored above 50
°
C for greater than 30 minutes, these ranges
must be re-calibrated. Otherwise, the 90 day and 1 year uncertainties
of these ranges double.
Temperature Coefficient
....................................... Temperature coefficient for temperatures outside tcal +5
°
C is 0.1/X/
°
C
of the 90-day specification (or 1-year, as applicable) per
°
C