Demo Instructions

 

 

 

Warning: defibrillators/external pacemakers are capable of emitting lethal 

high voltages/energies and should be operated only by trained professionals. 

  
IMPULSE 6000D/7000DP DEFIBRILLATOR/TRANSCUTANEOUS 
PACER ANALYZER  

 
 

INTRODUCTION  

 

25 reasons to differentiate Impulse 6000D/7000DP from all others 

 

Function

  

 

1.

 

Compatible with full range of  defibrillation technologies (monophasic, bi-phasic and 
pulsed bi-phasic) in the healthcare market 

2.

 

First-class measurement accuracy 

3.

 

Physiological ECG waveforms to test different AEDs 

4.

 

User-selectable pacer measurement algorithms for testing wide range of brand 
selections 

5.

 

Full compliment of built-in pacer testloads (from 50 to 1,500 ohms) 

6.

 

Flexible heart-rate setting facilitates rate meter & alarm testing (1 BPM per step) 

7.

 

Easy-to-use connection posts for 12 Lead ECG (10 electrodes) 

8.

 

Wide range of Arrhythmia selections 

9.

 

Auto-range defib & pacer measurement using DSP technology 

10.

 

Optional Ansur PC software for automation and standardization or test procedures, as 
well as print and data management/storage 

11.

 

Ready for external multiple patient defibrillation test loads (25 to175 ohms)  
(optional, available Q4, 2007) 

12.

 

Very low inductance (<2uH) test resistor 

 

Ergonomics 

1.   Portable and easy to carry  
2.

 

Rugged design 

3.

 

Intuitive user interface  

4.

 

Backlight, easy-to-read display  

5.

 

Large LCD with big numbers 

6.

 

USB port 

7.

 

Long-lasting, rechargeable NiMH battery  

8.

 

Modern, eye-catching new packaging by mechanical & industrial designers design 

 

Other Features

 

1.

 

DSP (Digital Signal Processor) based measurement   

2.

 

Safety standard compliance (IEC 61010): total electrical isolation 

Содержание IMPULSE 6000D

Страница 1: ...eart rate setting facilitates rate meter alarm testing 1 BPM per step 7 Easy to use connection posts for 12 Lead ECG 10 electrodes 8 Wide range of Arrhythmia selections 9 Auto range defib pacer measur...

Страница 2: ...d professionals 3 Future upgradeable firmware software and new waveforms 4 Global support network Low level ECG Power switch Navigator Function Pacemaker input 50 to 1500 ohms t LCD 1 Plug in defib pa...

Страница 3: ...hbutton The main menu appears on the analyzer s display The battery ICON in the upper right of the display indicates the relative charge level of the analyzer s internal battery If ICON is showing les...

Страница 4: ...capable of emitting lethal high voltages energies and should be operated only by trained professionals 3 To set up unit for test apply ECG leads to the ten AHA color on the left side of the post and...

Страница 5: ...B mode on the left panel then select a test a Press F1 ENERGY b Press F1 Set Wave and then select VFib from list using the UP DOWN keys c Press F2 Wave Conversion and select convert from list using th...

Страница 6: ...onals 3 The analyzer calculates the energy delivered over the load resistance and displays the result in joules under the result Press F4 for summary 4 Show on the monitor that ECG waveform is convert...

Страница 7: ...are available in the analyzer for performing this test Atrial fibrillation AFIB is the most representative clinical waveform for demonstration purposes Two selections are available AFIB Coarse is the...

Страница 8: ...be operated only by trained professionals 5 Power on the defibrillator Select the desired energy place the paddles and discharge Note for the purpose of this demonstration AFIB is converted to a norma...

Страница 9: ...ty in the defibrillator 1 Select F3 for CHARGE TIME test 2 Select F3 for MEASURE a Notice CHARGE TIME screen counting down 5 4 3 2 1 3 Select desired energy level and then charge defibrillator rillato...

Страница 10: ...d and sensitivity tests measures and displays refractory periods etc 1 Connect pacer to the analyzer through either defibrillator input 50 ohms only or pacer input 50 to 1500 ohms 2 Select PACER mode...

Страница 11: ...Turn pacer on and adjust pacer rate and output 8 Observe pacer Measurement result screen 9 Select F4 to view more tests F1 SENSITIVITY F2 REFRACTORY PERIOD Sensitivity test Demand sensitivity is the...

Страница 12: ...MANCE can choose different wave forms such as square pulse sine and triangle c F3 PACER INTERACTIVE Selections Under F3 are a Non capture the analyzer operates in continuous mode However every 10th pa...

Страница 13: ...e operated only by trained professionals b F2 PREMATURE c F3 VENTRICULAR d F4 MORE b Selects F4 again a Wave types i F1 CONDUCTION ii F2 TV PACED iii F3 R WAVE DETECTION iv Noise Immunity For more inf...

Отзывы: