Fluigent PRESSURE UNIT Скачать руководство пользователя страница 2

PRECAUTIONS

Place the product in an stable location with a level surface and good 
support.

If using the PRESSURE UNIT with other flow control systems than 
Fluigent pressure controllers, please check that the pressure in your 
fluidic system does not exceed the maximum pressure of the sensor 
being used.

Ensure to connect the PRESSURE UNIT to the PC before launching the 
software. Make sure to properly clean the fluidic path and disconnect 
the device from the PC to remove power supply.

Aria is a perfusion system which automates perfusion or timed 
injection protocols. It allows for the sequential delivery of up to 10 
different solutions at the desired flow rate into a microfluidic chip, 
perfusion chamber or petri dish.

Do not open PRESSURE UNIT device. Please refer all service issues to 
our Support department ([email protected])

Prevent any objects or liquid from entering the PRESSURE UNIT. This 
may cause a short-circuit or other malfunction. Failing to follow these 
instructions may:

• 

Expose the user to direct current/voltage if the device is powered. 
This may lead to damages.

• 

Void device's warranty

• 

Discharge our company from any liability regarding physical or 
device damages.

Содержание PRESSURE UNIT

Страница 1: ...USER S MANUAL PRESSURE UNIT INLINE PRESSURE SENSOR M...

Страница 2: ...s a perfusion system which automates perfusion or timed injection protocols It allows for the sequential delivery of up to 10 different solutions at the desired flow rate into a microfluidic chip perf...

Страница 3: ...QUICK START GUIDE 4 PRESSURE UNIT USER S MANUAL PRODUCT OVERVIEW 6 SPECIFICATIONS 7 WARRANTY TERMS 9 TECHNICAL SUPPORT 10...

Страница 4: ...g the provided connectics and tubing kit provided by Fluigent connect the PRESSURE UNIT into the fluidic path Note The fluid can flow following the direction of the arrow indicated on the PRESSURE UNI...

Страница 5: ...lers using LineUpTM local control or using Fluigent dedicated software on a computer and get the measured pressure in the fluidic path by the PRESSURE UNIT directly on Fluigent All in One software int...

Страница 6: ...bedirectlypluggedtoaPCwithUSBconnectionanddisplayin livethemeasurementonFluigentAll in Onesoftwareinterface Theuser s canoutputthisvalueforcustomsoftwareapplicationusingtheSoftware Development Kit 5 2...

Страница 7: ...ms Internal volume 22 L 22 L 22 L Compensated temperature range 0 to 50 C 0 to 50 C 0 to 50 C Connection fittings 1 4 28 Flat bottom 1 4 28 Flat bottom 1 4 28 Flat bottom Recommended tubing 1 16 OD 1...

Страница 8: ...Accuracy mean of max range 2 to 3 mbar 0 6 typ to 0 9 10 to 20 mbar 1 0 typ to 2 0 16 to 40 mbar 0 3 typ to 0 6 Zero shift 6 9 mbar 2 span 10 mbar 1 span 70 mbar 1 span Repeatability Hysteresis 1 4 mb...

Страница 9: ...time for Fluigent service representative to discuss and find a solution to fix the issue Repairs will be made remotely whenever possible If more action is needed the system will need to be sent back t...

Страница 10: ...your local office For tutorial videos about Fluigent products please visit Fluigent on YouTube Fluigent Fluigent S A S 33 1 77 01 82 65 Fluigent Inc 1 978 934 5283 Fluigent GmbH 49 3641 277 652 For a...

Страница 11: ...11 NOTES...

Страница 12: ...VERSION FEB 2021...

Отзывы: