8 - COMMUNICATION (OPTIONAL)
The functions described below deal with hardware that is not part of the standard delivery.
Programming of these functions does not have any effect if this hardware has not been installed.
Consult Appendix C and the Modbus communication protocol description for a detailed explanation.
BAUDRATE
81
For external control, the following communication speeds can be selected:
1200 - 2400 - 4800 - 9600 baud
BUS ADDRESS
82
For communication purposes, a unique identity can be attributed to every
F110-A. This address can vary from 1-255.
MODE
83
The communication protocol is Modbus ASCII or RTU mode. Select OFF,
to disable this communication function.
9 - OTHERS
TYPE OF MODEL
91
For support and maintenance it is important to have information about the
characteristics of the F110-A.
Your supplier will ask for this information in the case of a serious
breakdown or to assess the suitability of your model for upgrade
considerations.
VERSION SOFTWARE
92
For support and maintenance it is important to have information about the
characteristics of the F110-A.
Your supplier will ask for this information in the case of a serious
breakdown or to assess the suitability of your model for upgrade
considerations.
SERIAL NUMBER
93
For support and maintenance it is important to have information about the
characteristics of the F110-A.
Your supplier will ask for this information in the case of a serious
breakdown or to assess the suitability of your model for upgrade
considerations.
PASS CODE
94
All SETUP-values can be pass code protected.
This protection is disabled with value 0000 (zero).
Up to and including 4 digits can be programmed, for example 1234.
TAGNUMBER
95
For identification of the unit and communication purposes, a unique tag
number of maximum 7 digits can be entered.