FW-F093-P-M_v0404_01_EN.docx
For the Operator, the following functions are available:
•
Display engine speed / running hours or engine speed only or running hours only
This is the main display information of the F093-P. After selecting any other information, it will
always return to this main display automatically.
Running hours is displayed on the upper-line of the display and engine speed on the bottom
line.
It is possible to display engine speed only with the large 17mm digits; in this instance press
the SELECT-key to read the running hours.
When "-------" is shown, then the engine speed value is too high to be displayed. The arrows
indicate the increase/decrease of the engine speed trend.
•
Clear running hours
The value for running hours can be re-initialized. To do so, press CLEAR twice. After
pressing CLEAR once, the flashing text "PUSH CLEAR" is displayed. To avoid re-initialization
at this stage, press another key than CLEAR or wait for 20 seconds.
Re-initialization of running hours DOES NOT influence the accumulated running hours.
If pressing CLEAR twice does not clear the running hours, the F093-P is configured not to
allow this in Operation mode.
•
Display accumulated running hours
When the SELECT-key is pressed, running hours and accumulated running hours are
displayed. The accumulated running hours cannot be re-initialized. The value will count up to
99,999,999,999. The unit and number of decimals are displayed according to the
configuration settings for running hours.
•
Programming the engine speed or running hours alarm values (in Operation mode)
This function might not be available due to configuration settings.
When the SELECT-key is pressed a few times, following engine speed and running hours
alarm values are displayed:
-
low engine speed alarm: enter here 830 RPM for example,
-
high engine speed alarm: enter here 5000 RPM for example,
-
accumulated running hours, enter here 1000 HOURS for example.
To change the alarm value, the following procedure must be executed:
1) press PROG: the word "PROGRAM" will flash or a password will be requested,
2) use
to select the digits and
to increase that value,
3) confirm the new alarm value by pressing ENTER.
Fig. 4: Example of display information during programming minimum engine speed.
When data is altered but ENTER has not been pressed yet, then the alteration can still be
cancelled by waiting for 20 seconds or by pressing ENTER during three seconds: the former
value will be reinstated.
•
Engine speed alarm
When the actual engine speed is outside the allowed range, an alarm message will be
displayed indicating the type of alarm: "RPM LO" or "RPM HI".
The alarm is terminated automatically as soon as the engine speed is within its range again.
•
Running hours alarm
When the total running hours have reached the allowed range, an alarm message will be
displayed indicating the type of alarm.