![Fluidwell F018-P Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/fluidwell/f018-p/f018-p_manual_2308988016.webp)
Page 16
FW-F018-P-M_v0404_01_EN.docx
3.3.5
EXPLANATION OF SETUP-MENU 4 - DISPLAY
SETUP
FUNCTIONS
AND
VARIABLES
4
DISPLAY
4.1
FUNCTION
The large 17mm digits can be set to display: flow rate, total or
accumulated total.
By pressing SELECT you can scroll through the various values. After
30 seconds of inactivity, the display will return to show its main
information.
4.2
LCD NEW
The calculation of the display-information influences the power
consumption significantly. When the application does not require a
fast display update, it is
strongly advised
to select a slow refresh
rate. Please understand that NO information will be lost; every pulse
will be counted and the output signal will be generated in the normal
way.
The following can be selected:
Fast - 1 sec - 3 sec - 15 sec - 30 sec - off.
Example battery life-time with a coil pick-up:
•
1kHz pulse and FAST update: about 2 years.
•
1kHz pulse and 1 sec update: about 5 years.
The functions below will only effect the optional LED-backlight.
4.3
BACKLIGHT
If a LED backlight has been supplied, it can be turned on or off.
4.4
BACKLIGHT ALARM
In case the F018-P generates a flow rate alarm, the backlight can be
set to change to red. Following selections are available:
ON:
OFF:
FLASH:
during flow rate alarm the color is red.
during flow rate alarm the color is according to setting 43.
during flow rate alarm the color flashes red.
4.5
BL. BRIGHTNESS
The backlight brightness is adjustable. The following can be selected:
1
– 5 (where 1 is minimum and 5 is maximum brightness)
4.6
BATTERY MODE
The F018-P has two modes: operational or shelf.
After "shelf" has been selected, the F018-P can be stored for several
years; it will not process the sensor signal; the display is switched off
but all settings and totals are stored. In this mode, power consumption
is extremely low.
To wake up the F018-P again, press the SELECT/
key twice.