![fluidra Certikin iSAVER+ DVSD03 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/fluidra/certikin-isaver-dvsd03/certikin-isaver-dvsd03_manual_2308890009.webp)
9
Troubleshooting / protection & error codes
The device may show error codes in certain circumstances – these codes could signify a fault, or may be an alert to protect the
device form damage.
Code
Description
Analysis / Action
E001
Abnormal input voltage
No fault – consult electrician
E002
Output over current
See note 1 or contact supplier
E101
Heat sink over heat
See note 1 or contact supplier
E102
Heat sink sensor error
Contact supplier
E103
Master drive board error
See note 1 or contact supplier
E201
Circuit board error
Contact supplier
E202
Master board EEPROM reading failure
Contact supplier
E203
RTC time reading error
Contact supplier
E204
Keyboard EEPROM reading failure
Contact supplier
E205
Communication error
Contact supplier
AL01
Auto speed reduction against high temperature
See note 2
Note 1:
When the cause resulting in error code E002/E101/E103 lifts, the device will resume working correctly – however this
pattern will only repeat for three occasions – on the fourth occasion the device will stop working. To resume operation, turn off all
power, then re-establish power and re-start the unit. If problems persist contact your supplier for assistance.
Note 2:
AL01 is not an error indication. When this code appears, the device will automatically switch to a lower speed to self-
protect against internal high temperatures. When the temperature drops back to 65°C the inverter will resume at the pre-set speed.