Troubleshooting / protection & error codes

The device may show error codes in certain circumstances – these codes could signify a fault, or may be an alert to protect the 
device form damage.

Code

Description

Analysis / Action

E001

Abnormal input voltage

No fault – consult electrician

E002

Output over current

See note 1 or contact supplier

E101

Heat sink over heat

See note 1 or contact supplier

E102

Heat sink sensor error

Contact supplier

E103

Master drive board error

See note 1 or contact supplier

E201

Circuit board error

Contact supplier

E202

Master board EEPROM reading failure

Contact supplier

E203

RTC time reading error

Contact supplier

E204

Keyboard EEPROM reading failure

Contact supplier

E205

Communication error

Contact supplier

AL01

Auto speed reduction against high temperature

See note 2

Note 1:

 When the cause resulting in error code E002/E101/E103 lifts, the device will resume working correctly – however this 

pattern will only repeat for three occasions – on the fourth occasion the device will stop working. To resume operation, turn off all 
power, then re-establish power and re-start the unit. If problems persist contact your supplier for assistance.

Note 2: 

AL01 is not an error indication. When this code appears, the device will automatically switch to a lower speed to self-

protect against internal high temperatures. When the temperature drops back to 65°C the inverter will resume at the pre-set speed.

Содержание Certikin iSAVER+ DVSD03

Страница 1: ...ERENCE Notice to Installer This document contains important information about the installation operation and safe use of this product this information must be read before the installation and start up of this product Once the product has been installed this document must be given to the owner operator of this equipment ...

Страница 2: ...h a HIGH level of risk which if not avoided WILL result in death or serious injury DANGER This notice signifies a hazard with a MEDIUM level of risk which if not avoided COULD result in death or serious injury WARNING This notice signifies a hazard with a LOW level of risk which if not avoided COULD result in minor or moderate injury This notice signifies a potential risk of damage to the product ...

Страница 3: ...RE USING THE CORRECT MODEL WARNING This device is designed for use ONLY with swimming pool pumps with a permanent split capacitor motor Fig 1 below shows a wiring schematic for a typical single speed swimming pool pump motor Running capacitor Main Winding Auxiliary Winding Fig 1 Typical single speed swimming pool pump motor schematic WARNING This device IS NOT COMPATIBLE WITH a Single phase motors...

Страница 4: ...h a regulated waste disposal and recycling centre please consult your local authority for full advice List of supplied components iSaver inverter Power supply cable pre wired into inverter Mounting template fixings screws and plugs Installation WARNING Upon receipt of this device check for any damage which may have occurred in transit If any damage is found DO NOT PROCEED WITH INSTALLATION and con...

Страница 5: ...plugs and fixings supplied to create the mounting position for the unit Test mount and then remove From the rear of the inverter remove the recessed screws which hold the outer cover to the body Carefully lift and remove the outer cover in order to gain access to the internal terminal connections WARNING A qualified electrician must carry out all electrical wiring in accordance with local electric...

Страница 6: ...n the table below The pool pump can be run at a constant speed by choosing one of these modes via the M function or it can be run via the setting up of four timers for daily operation each with an individual speed Mode M Speed Range Default Speed Night slow 1200 1650rpm 1400rpm Day medium 1700 2400rpm 2000rpm Backwash high 2450 2900rpm 2900rpm Useful notes on general operation If inactive for 1 mi...

Страница 7: ... order to benefit from this the iSaver allows the setting of up to 4 timers These are established as follows Step 1 Press to begin using the timer function Step 2 Use and to set the current clock time Step 3 Press to toggle to timer 1 and use and to set the start times for that timer Use to toggle to the stop times use and to set that time Use to toggle to the speed setting Note Each setting is sa...

Страница 8: ...escription Default Setting Setting Range 1 Priming time 1 minute 1 10 minutes by 1 minute increments 2 Minimum rpm 1200rpm 1200 2000rpm by 100rpm increments Maintenance This device carries no serviceable or maintenance needing parts In the event of a fault or failure which cannot be resolved via these instructions please contact your supplier WARNING Because of high voltage conversion components c...

Страница 9: ...ime reading error Contact supplier E204 Keyboard EEPROM reading failure Contact supplier E205 Communication error Contact supplier AL01 Auto speed reduction against high temperature See note 2 Note 1 When the cause resulting in error code E002 E101 E103 lifts the device will resume working correctly however this pattern will only repeat for three occasions on the fourth occasion the device will st...

Страница 10: ...10 Notes ...

Страница 11: ...11 Notes ...

Страница 12: ...00 info certikin co uk www certikin co uk Certikin International Ltd Witan Park Station Lane Industrial Estate Witney Oxfordshire OX28 4FJ Item manufactured by Aquagem Electric Limited Guangzhou China JANUARY 2020 ...

Отзывы: