fluidra 27802-S3 Скачать руководство пользователя страница 7

 
 
 

 

 

FLUIDRA USA 

8525 Mallory Road  

Jacksonville, FL 32220  

Phone: (904) 378-0999 

Fax: (904) 378-0408 

 

to see some types of damage that may have occurred. It is important to test the system without sand first to check for 
leaks. Fill the system with water, replace the lid and gasket. Run the system as normal and check for leaks. 

If there is a 

problem with the test, contact Fluidra customer service immediately. 

If sand is added before the test and there is a 

problem with the filter, the sand will need to be evacuated for inspection. Fluidra 

will not pay

 for the removal and 

replacement of the sand under warranty, nor will Fluidra provide the labor to evacuate and replace the sand for repair 
work done due to transportation or installation damage. This also a good chance to check all plumbing for the system. 

Do 

not drain the water from the fitler after the testing sequence. 
 

3.5 Installation of the media 

After the testing has been finished and the system is 100% operation, we need to add the filteration media required. 
Remove the lid and gasket from the fitler as before. The filter should be full of water at this time. If the filter is not full of 
water, the filter needs to be filled at least to the diffusers before adding the media. The proper amount of media for each 
filter is listed in 

Fig. 2-1

. If a diffuser head is directly underneath the manhole cover, remove diffuser assembly or cover 

with plastic and tape to prevent media for entering the plumbing. 
 
Now, replace the lid and gasket to the top of the filter. Be sure the cover is free of sand. If the cover is not free of sand, the 
gasket will not seat properly and could cause the filter to leak at the lid. Put the filter into backwash mode (see next 
section) and run for about 5 to 6 minutes. This will level the sand inside the fitler. Put the valves into the filter position and 
the system is ready for operation. 
 

4.  Operation 

4.1 Filtration 

Note: 

There are many different styles of manifolds and multiport valves available for the Aster line of filters. 

!!!NOTE, 

Tank must be full of water prior to start of the Filtration Mode!!! 

With the pump off, arrange the valves or multiport into the filtration position. Normally, while a filter is running, inlet 
pressure is 12 to 15 psi and the outlet pressure is 6 to 9 psi. This is normal pressure when the filter is clean. As the filter 
media cleans the water, it traps particles of debris from the water inside the filter. These particles will make it more 
diffucult for water to pass through resulting in less water flow and a higher filter pressure. When the pressure rise is 7 psi 
above starting pressure, it is time to backwash the system. 

4.2 Backwash 

In filter beds, there are thousands of channels for water to pass through, trapping particulate matter. As time passes these 
channels become blocked and it becomes necessary to clean the filter bed to restore the filter to its optimum working 
condition by discharging the trapped particles to drain. The velocity of the water for the backwash cycle should be the 
same as for the filtration mode. This velocity should never exceed 20 GPM/ Ft² of filtration surface area to prevent 
discharging sand to drain and possibly damaging the filter. 

The backwash cycle should run for 3 to 5 minutes. It is advisable to fit a sight glass in the drain line close to the filter so 
that when backwashing is carried out, one can see the water clearing and stop the backwash when the water is clean to 
avoid an unnecessary waste of water. 

To carry out the backwash, stop the pump, set the valves into the backwash position and restart the pump. Once 
backwash is complete turn off pump and position valves to retain water inside the filter vessel. Reposition the valves to 
the filter mode and start the pump immediately. If water is allowed to escape the fitler vessel, the sand bed will be 
disturbed by the introduction of air. 

!!!Note, the filter tank must be full of water after backwash and before starting 

the filtration mode!!! 

4.3 Empty 

When it is necessary to empty the pool, it is possible to drain through the filter system. The water can be redirected to 
waste using the multiport valve on the filter. The valve can be positioned in the drain position and the filter will by-pass the 

Содержание 27802-S3

Страница 1: ...2016 Fluidra USA 2 16 2016 Installation Operation Manual ...

Страница 2: ... 2 Characteristics Dimensions Media Requirements 4 3 Installation 4 3 1 General installation notes 4 3 2 Filter Installation 5 3 3 Installation of the Pressure Gauge 5 3 4 Testing of filter 5 3 5 Installation of the media 6 4 Operation 6 4 1 Filtration 6 4 2 Backwash 6 4 3 Empty 6 4 4 Isolate Close 7 5 Changing of the filter media 7 6 Other recommendations of Interest 7 7 Graph of Filter Head Loss...

Страница 3: ...ors the size and shape of the media the media bed depth characteristics of the media such as granular size density etc A most important paramenter is the water filtration rate Other factors affecting the selection of a filter are the materials used for its construction the working temperature and the operating pressures 1 2 Fluidra Filters Manufactured from polyester resin and fiberglass they are ...

Страница 4: ... the surface area required by 10 or more this will allow better water quality Whenever possible use more than one filter in conjunction this will allow one filter to be serviced while one is still functioning When sizing the plumbing for a filtration package be sure to keep in mind that the velocity of the water pipes is very important Each state or country may have different maximums for velocity...

Страница 5: ...to their weight and size it is recommended that mechanical means be employed to move the filters into position It is also very important to inspect the filters carefully before installing Make noe on the shipping paperwork if there is any damage to the packaging Polyester filters can be damaged easily during transportation and is the responsibility of the installer to inspect at the time of delive...

Страница 6: ...ponents have loosened It is now necessary to remove the filter lid and enter the filter being careful not to break any of the connections By hand check the tightness laterals in the bottom of the filter making sure they are firmly tightened Also while in the filter check for any cracks o breaks in the body of the filter or the PVC internals that might have occurred during transportation using a fl...

Страница 7: ...rs NOTE Tank must be full of water prior to start of the Filtration Mode With the pump off arrange the valves or multiport into the filtration position Normally while a filter is running inlet pressure is 12 to 15 psi and the outlet pressure is 6 to 9 psi This is normal pressure when the filter is clean As the filter media cleans the water it traps particles of debris from the water inside the fil...

Страница 8: ...equired in Figure 2 1 of this manual 6 Other recommendations of Interest Fluidra filters are virtually corrosion resistant and need very little maintenance It is advisable to clean the surface of the filter every 2 years or whenever dirty with a mild soap and water to maintain the looks of the fitler Every filter is equipped with a manual air vent fitted in the top of the filter In addition each f...

Страница 9: ...8 FLUIDRA USA 8525 Mallory Road Jacksonville FL 32220 Phone 904 378 0999 Fax 904 378 0408 Fig 4 1 8 Replacement Part Drawings and Part Numbers ...

Страница 10: ...9 FLUIDRA USA 8525 Mallory Road Jacksonville FL 32220 Phone 904 378 0999 Fax 904 378 0408 ...

Страница 11: ...10 FLUIDRA USA 8525 Mallory Road Jacksonville FL 32220 Phone 904 378 0999 Fax 904 378 0408 ...

Страница 12: ...11 FLUIDRA USA 8525 Mallory Road Jacksonville FL 32220 Phone 904 378 0999 Fax 904 378 0408 ...

Страница 13: ...12 FLUIDRA USA 8525 Mallory Road Jacksonville FL 32220 Phone 904 378 0999 Fax 904 378 0408 ...

Страница 14: ... Ø1 05m to Ø2m from the third year up to tenth year as indicated below This Guarantee Extension is governed by the following terms 2 4 1 Coverage of the Guarantee Extension by the Manufacturer In the event of any defect or non conformity in the container of the filter the manufacturer will repair or replace the filter as he sees fit 2 4 2 Replacement will construe that the purchaser accepts the pa...

Страница 15: ... light bulbs etc the stipulations in the documentation provided with the Product will apply 3 3 The guarantee does not cover those cases when the Product I has been handled incorrectly II has been repaired serviced or handled by non authorised people or III has been repaired or serviced not using original parts or IV has been installed or started up in a wrong way 3 4 In cases where the defect of ...

Отзывы: